4. Enter the
Fuse-IP Server Address
, which is the public static IP address of the server codec
at the studio. Then enter the server codec's serial number in the
Server Serial Number
text box. Leave the default
Fuse-IP Port
as
8999
in most situations unless this port is
already in use, e.g. you have multiple codecs behind a firewall using Fuse-IP, therefore you
need to allocate a different port for each Fuse-IP tunnel. Note: the port number on the client
and server codecs must be the same. Configure the
Inactivity Timeout
if you want to turn
the Fuse-IP tunnel off after a predetermined time period to save data, then click
Save
. Note:
Inactivity Timeout
can be configured from 0 to 1440 minutes. Enter
0
to disable the
timeout.
5. Click the
On/Off
button for Fuse-IP to create a Fuse-IP tunnel between the server and client
codecs. Note:
Connected
should be displayed after a few seconds if both codecs are
configured correctly and Fuse-IP is enabled on both codecs.
6. The status indicator is orange when Fuse-IP is enabled but no tunnel is created. It turns green
when a tunnel is active.
Содержание Genie Distribution
Страница 27: ...27 Tieline Research Pty Ltd 2020 Genie Distribution WNET Manual v3 Connect Menu...
Страница 50: ...50 Genie Distribution WNET Manual v3 Tieline Research Pty Ltd 2020 2 Select Yes and press the button...
Страница 126: ...126 Genie Distribution WNET Manual v3 Tieline Research Pty Ltd 2020...
Страница 365: ...365 Tieline Research Pty Ltd 2020 Genie Distribution WNET Manual v3 IP Connection Bit rates Supported...
Страница 426: ...Genie Distribution WNET Manual v3 426 Tieline Research Pty Ltd 2020 WNET LAN port 15 X XLR in out 15...