197
© Tieline Research Pty. Ltd. 2020
Genie Distribution WNET Manual v3
2. This audio stream connection in the wizard will allow the codec to dial and connect the second
audio stream. Enter the name of the connection in the text box, then click
Next
.
3. Continue through the steps in the wizard to complete configuration in the same way as the first
peer-to-peer connection was configured. Click
Save Program
to save all program settings, then
click
Finish
to exit the wizard.
Important Notes:
·
Session Port 9002
and
Remote Audio Port 9010
are used by default for the second
IP connection.
·
Session Port 9002
and
Remote Audio Port 9020
are used by default for the third IP
connection.
·
Routing of inputs to encoders/outputs can be adjusted using the
Matrix Editor panel
in the Toolbox HTML5 Web-GUI.
·
If you connect to a G3 codec using IP2 you will need to change the session port on the
Genie Distribution codec to 9012 for the second audio stream connection, as this is
used by default on G3 codecs for IP2.
4. The newly created program can be loaded from within the
Program Manager panel
and
Connections panel
.
Select and connect audio streams
Connections
panel
, or connect the program manually using the codec front panel.
Содержание Genie Distribution
Страница 27: ...27 Tieline Research Pty Ltd 2020 Genie Distribution WNET Manual v3 Connect Menu...
Страница 50: ...50 Genie Distribution WNET Manual v3 Tieline Research Pty Ltd 2020 2 Select Yes and press the button...
Страница 126: ...126 Genie Distribution WNET Manual v3 Tieline Research Pty Ltd 2020...
Страница 365: ...365 Tieline Research Pty Ltd 2020 Genie Distribution WNET Manual v3 IP Connection Bit rates Supported...
Страница 426: ...Genie Distribution WNET Manual v3 426 Tieline Research Pty Ltd 2020 WNET LAN port 15 X XLR in out 15...