337
© Tieline Research Pty. Ltd. 2020
Genie Distribution WNET Manual v3
Enabling Data
Data
is disabled by default and must be enabled to allow contact closure operation and
transmission of RS232 data. Select
Enable Auxiliary Data
when creating a program in the
Program Manager panel
or
Connections panel
to enable out-of-band RS232 data and activate
rules employing relay reflection over a connection. It is also possible to enable data using the front
panel of the codec:
1. Press the
HOME
button to return to the
Home
screen
2. Use the navigation buttons on the front panel to select
Connect
and press the
button
3. Select
IP
and press the
button
4. Select your preferred
IP Mode
and press the
button.
5. Use the down
navigation button to select
Setup
and press the
button.
6. Navigate to
Data
and press
to toggle between
Enabled
and
Disabled
.
For more information please see
Important Notes for Rules:
·
The codec has 4 physical
CONTROL PORT GPIOs
; 7 Tieline and WheatNet virtual
inputs (1-7); 64 Tieline virtual logic outputs; and, 64 virtual WheatNet logic outputs
(these allow Tieline WheatNet-IP enabled codecs to activate functions across a
WheatNet-IP network). See
·
Virtual inputs 5-7 can be activated by pressing the
F1
button and
KEYPAD
buttons 1-3.
·
A non-WheatNet-IP Tieline codec can be configured to trigger a WheatNet LIO in a
Tieline WheatNet-IP codec.
·
Tieline WheatNet-IP codecs require Wheatstone Razor firmware version 1.4.22 or later
to support WheatNet LIOs. In addition, the WheatNet-IP codec must have the
WNet
Enable LIO
checkbox
selected in the
Options panel
of the HTML5 Toolbox Web-GUI.
·
Relay reflection is not available for SIP and Multicast Client programs.
·
Connection-related rules are not displayed in
Answer only
audio streams.
·
Rules intended to activate dialing will not be valid in
Answer only
programs or audio
streams.
·
For more details about rules see
Configure Rules with the Program Manager Panel
To configure program or stream level rules follow the instructions in this user manual for setting up
connections.
Program Level Rules
In the
Program Manager panel
wizard use the
Configure Program Rules
screen to
configure program level rules. The rules available are displayed in the following image.
Содержание Genie Distribution
Страница 27: ...27 Tieline Research Pty Ltd 2020 Genie Distribution WNET Manual v3 Connect Menu...
Страница 50: ...50 Genie Distribution WNET Manual v3 Tieline Research Pty Ltd 2020 2 Select Yes and press the button...
Страница 126: ...126 Genie Distribution WNET Manual v3 Tieline Research Pty Ltd 2020...
Страница 365: ...365 Tieline Research Pty Ltd 2020 Genie Distribution WNET Manual v3 IP Connection Bit rates Supported...
Страница 426: ...Genie Distribution WNET Manual v3 426 Tieline Research Pty Ltd 2020 WNET LAN port 15 X XLR in out 15...