372
Genie Distribution WNET Manual v3
© Tieline Research Pty. Ltd. 2020
Configuring Tieline FEC in the Codec
1. Press the
HOME
button to return to the
Home
screen.
2. Use the navigation buttons on the front panel to select
Connect
and press the
button.
3. Select
IP
and press the
button.
4. Select
Tieline
and press the
button.
5. Use the down
navigation button to select
Setup
and press the
button.
6. Navigate to
FEC
and press
.
7. Select the local codec FEC setting in the
Local FEC
screen and press
.
8. Select the remote codec FEC setting in the
Remote FEC
screen and press
.
Important Note:
FEC can only be configured for use with the Music and MusicPLUS
algorithms.
Configuring RFC 2733 FEC in the Codec (Sessionless Connections only)
1. Press the
HOME
button to return to the
Home
screen.
2. Use the navigation buttons on the front panel to select
Connect
and press the
button.
3. Select
IP
and press the
button.
4. Select
Sessionless
and press the
button.
5. Select
Peer-to-Peer
and press the
button.
6. Use the down
navigation button to select
Setup
and press the
button.
7. Navigate to
FEC
and press
.
8. Select
Enable
and press
.
9. Select the
FEC Percentage
and press
.
10. Select the
FEC Delay
used by the codec and press
.
Important Notes:
·
The
FEC Delay
configured should take into account the packet arrival (jitter buffer)
strategy at the remote codec. For example, if the maximum jitter buffer at the remote
codec is 1000 ms, the FEC Delay setting should be lower, to ensure there is enough
time for FEC packets to arrive and replace lost packets prior to audio playout.
·
By default, the codec will use the audio stream IP address as the remote FEC IP
address as well. This can be adjusted in the
Program Manager panel
in the HTML5
Toolbox web-GUI.
·
The default local and remote UDP audio FEC ports are 9002.
·
Any of the available algorithms can be selected when configuring RFC 2733 FEC in the
codec.
How does FEC work?
If you enter a FEC setting of 20% and you are losing one packet in every five sent, the lost packet
will be replaced by FEC to maintain the quality of the connection. If you are losing more packets
than this, say one in three, it will be necessary to increase the FEC setting to 33% to compensate.
Note
: There is an inverse relationship between FEC settings and the jitter-buffer millisecond setting
that you use for IP connections.
So why not use 100% FEC every time? The answer is because you need twice the bit rate to
achieve full redundancy and depending on the link conditions, this could potentially cause more
Содержание Genie Distribution
Страница 27: ...27 Tieline Research Pty Ltd 2020 Genie Distribution WNET Manual v3 Connect Menu...
Страница 50: ...50 Genie Distribution WNET Manual v3 Tieline Research Pty Ltd 2020 2 Select Yes and press the button...
Страница 126: ...126 Genie Distribution WNET Manual v3 Tieline Research Pty Ltd 2020...
Страница 365: ...365 Tieline Research Pty Ltd 2020 Genie Distribution WNET Manual v3 IP Connection Bit rates Supported...
Страница 426: ...Genie Distribution WNET Manual v3 426 Tieline Research Pty Ltd 2020 WNET LAN port 15 X XLR in out 15...