as UDP audio port 9010 by default for the second audio stream connection.
Click to deselect the
Automatic
check-box to adjust this setting. A codec
dialing this connection and using the port specified will always be routed to
output 2 on the codec receiving the call.
Click to configure:
·
Auto Jitter Adapt
and the preferred auto jitter setting using the drop-down arrow for
Buffer priority
. It is also possible to configure the
Minimum depth
and
Maximum
depth
of jitter over the connection. See
·
Alternatively, select a
Fixed Buffer Level
and enter the
Jitter Depth
, which must
be between 12ms and 5000ms depending on the algorithm you select.
ISDN module answering settings are used if you select ISDN as the connection transport.
For more details see Configuring ISDN Answering.
POTS module answering settings are used if you select POTS as the connection
transport. For more details see
4. Continue through the steps in the wizard to complete configuration in the same way as the first
connection was configured.
Important Notes:
·
Session Port 9002
and
Remote Audio Port 9010
are used by default for the second
IP connection.
·
Session Port 9002
and
Remote Audio Port 9020
are used by default for a third IP
connection when configured.
·
Routing of inputs to encoders/outputs can be adjusted using the
Matrix Editor panel
in the Toolbox HTML5 Web-GUI.
·
If you connect to a G3 codec using IP2 you will need to change the session port on the
Genie Distribution codec to 9012 for the second audio stream connection, as this is
used by default on G3 codecs for IP2.
5. Click
Save Program
to save all program settings, then click
Finish
to exit the wizard. The
newly created program can be loaded from within the
Program Manager panel
and
Connections panel
. When this program is loaded any codec connecting using IP1 (using
default Tieline IP port settings) will be routed to output 1 on the codec and a codec dialing in
using IP2 will be routed to output 2.
Содержание Genie Distribution
Страница 27: ...27 Tieline Research Pty Ltd 2020 Genie Distribution WNET Manual v3 Connect Menu...
Страница 50: ...50 Genie Distribution WNET Manual v3 Tieline Research Pty Ltd 2020 2 Select Yes and press the button...
Страница 126: ...126 Genie Distribution WNET Manual v3 Tieline Research Pty Ltd 2020...
Страница 365: ...365 Tieline Research Pty Ltd 2020 Genie Distribution WNET Manual v3 IP Connection Bit rates Supported...
Страница 426: ...Genie Distribution WNET Manual v3 426 Tieline Research Pty Ltd 2020 WNET LAN port 15 X XLR in out 15...