375
© Tieline Research Pty. Ltd. 2020
Genie Distribution WNET Manual v3
3.
Program Manager panel
: Configure stream level rules for each audio stream as you
proceed through the
Program Manager panel
wizard.
Important Note:
A non-WheatNet-IP Tieline codec can be configured to trigger a logic IO
in a Tieline Genie Distribution and Merlin PLUS WheatNet-IP codec, as well as 4 physical
CONTROL PORT
GPIOs. The codec has:
·
4 physical
CONTROL PORT
GPIOs.
·
7 Tieline and WheatNet virtual inputs (1-7). Note: Virtual inputs 5-7 can be activated
by pressing the
F1
button and
KEYPAD
buttons 1-3.
·
64 Tieline virtual logic outputs. Note: Tieline logic IOs (LIOs) are only supported
between Genie, Merlin, ViA and Bridge-IT IP codecs.
·
64 virtual WheatNet logic outputs available in Genie Distribution and Merlin PLUS
WheatNet-IP codecs. These allow Tieline WheatNet-IP enabled codecs to activate
functions across a WheatNet-IP network.
See the section titled
Configuring RS232 Data
Once
Data
is enabled, the codec can be connected to external devices and transport RS232-
compatible data via the serial port on the rear panel of the codec.
1. Press the
SETTINGS
button.
2. Navigate to
System
and press
.
3. Select
RS232 Config
and press
.
4. Use the navigation buttons to select the correct baud rate.
5. Select
Enable
for flow control and press
to save all settings.
Important Notes:
·
When connecting to G3 codecs over IP, ISDN or POTS only in-band data is available via
the Music and MusicPLUS algorithms. See
·
It is important that you enable serial port flow control within the codec. Flow control
regulates the flow of data through the serial port. If disabled, data will flow unregulated
and some may be lost.
·
Ensure you match the serial port baud rate to match the rate of the external device you
are connecting to. Ideally the settings on both codecs should match, or you could have
data overflow issues.
·
Only the dialing codec needs to be configured to send RS232 data to another Tieline G5
codec. Session data sent from the dialing codec configures the answering codec.
21.13
Monitor Control Port I/O Status
It is possible to monitor the status of the four relay inputs and four opto-isolated outputs available
using the DB15
CONTROL PORT IN / OUT
connector. To monitor status:
1. Press the
SETTINGS
button.
2. Use the navigation buttons to select
Control Port I/O
and press the
button.
3. Select
Inputs
and then press the
button to view input status.
Содержание Genie Distribution
Страница 27: ...27 Tieline Research Pty Ltd 2020 Genie Distribution WNET Manual v3 Connect Menu...
Страница 50: ...50 Genie Distribution WNET Manual v3 Tieline Research Pty Ltd 2020 2 Select Yes and press the button...
Страница 126: ...126 Genie Distribution WNET Manual v3 Tieline Research Pty Ltd 2020...
Страница 365: ...365 Tieline Research Pty Ltd 2020 Genie Distribution WNET Manual v3 IP Connection Bit rates Supported...
Страница 426: ...Genie Distribution WNET Manual v3 426 Tieline Research Pty Ltd 2020 WNET LAN port 15 X XLR in out 15...