Alarm Dissemination Panel
Alerts for each alarm severity level are configured using the
Alarm Dissemination
panel
.
Feature
Description
1
List of alarm severity levels
Click to select an alarm severity level to configure it.
2 Front
panel
alarm
&
Toolbox
check-box
Select the check-box (default enabled) to deliver front panel
ALARM LED
notifications and HTML5 Toolbox Web-GUI
alarm notifications.
3 Close
button
Click to close the panel.
4 Relay
drop-down selection
Click the drop-down arrow to select a relay to open when an
alarm using the current severity level is activated.
5
SNMP Trap Target text-box
Click in the text box in edit mode to enter the SNMP trap
target for alarms using the currently selected severity level.
6 Edit
/
Save
button
Click to edit alarm dissemination settings, or save configured
settings when in edit mode.
7 Send SNMP trap
check-box
Select the check-box to enable SNMP traps to be sent (for
alarms using the selected severity level).
Содержание Genie Distribution
Страница 27: ...27 Tieline Research Pty Ltd 2020 Genie Distribution WNET Manual v3 Connect Menu...
Страница 50: ...50 Genie Distribution WNET Manual v3 Tieline Research Pty Ltd 2020 2 Select Yes and press the button...
Страница 126: ...126 Genie Distribution WNET Manual v3 Tieline Research Pty Ltd 2020...
Страница 365: ...365 Tieline Research Pty Ltd 2020 Genie Distribution WNET Manual v3 IP Connection Bit rates Supported...
Страница 426: ...Genie Distribution WNET Manual v3 426 Tieline Research Pty Ltd 2020 WNET LAN port 15 X XLR in out 15...