Power, Reset, and Clock Management
8.1.12.2.45 CM_WKUP_WKUP_M3_CLKCTRL Register (offset = B0h) [reset = 2h]
CM_WKUP_WKUP_M3_CLKCTRL is shown in
and described in
This register manages the WKUP M3 clocks.
Figure 8-128. CM_WKUP_WKUP_M3_CLKCTRL Register
31
30
29
28
27
26
25
24
Reserved
R-0h
23
22
21
20
19
18
17
16
Reserved
STBYST
Reserved
R-0h
R-0h
R-0h
15
14
13
12
11
10
9
8
Reserved
R-0h
7
6
5
4
3
2
1
0
Reserved
MODULEMODE
R-0h
R-2h
LEGEND: R/W = Read/Write; R = Read only; W1toCl = Write 1 to clear bit; -n = value after reset
Table 8-136. CM_WKUP_WKUP_M3_CLKCTRL Register Field Descriptions
Bit
Field
Type
Reset
Description
31-19
Reserved
R
0h
18
STBYST
R
0h
Module standby status.
0x0 = Func : Module is functional (not in standby)
0x1 = Standby : Module is in standby
17-2
Reserved
R
0h
1-0
MODULEMODE
R
2h
Control the way mandatory clocks are managed.
664
Power, Reset, and Clock Management (PRCM)
SPRUH73H – October 2011 – Revised April 2013
Copyright © 2011–2013, Texas Instruments Incorporated