Ethernet Subsystem Registers
14.5.1.1 IDVER Register (offset = 0h) [reset = 290104h]
IDVER is shown in
and described in
ADDRESS LOOKUP ENGINE ID/VERSION REGISTER
Figure 14-15. IDVER Register
31
30
29
28
27
26
25
24
IDENT
R-0
23
22
21
20
19
18
17
16
IDENT
R-0
15
14
13
12
11
10
9
8
MAJ_VER
R-0
7
6
5
4
3
2
1
0
MINOR_VER
R-0
LEGEND: R/W = Read/Write; R = Read only; W1toCl = Write 1 to clear bit; -n = value after reset
Table 14-25. IDVER Register Field Descriptions
Bit
Field
Type
Reset
Description
31-16
IDENT
R-0
0
ALE Identification Value
15-8
MAJ_VER
R-0
0
ALE Major Version Value
7-0
MINOR_VER
R-0
0
ALE Minor Version Value
1241
SPRUH73H – October 2011 – Revised April 2013
Ethernet Subsystem
Copyright © 2011–2013, Texas Instruments Incorporated