McASP Registers
22.4.1.14 Receive Format Unit Bit Mask Register (RMASK)
The receive format unit bit mask register (RMASK) determines which bits of the received data are masked
off and padded with a known value before being read by the CPU or DMA. The RMASK is shown in
and described in
.
Figure 22-52. Receive Format Unit Bit Mask Register (RMASK)
31
0
RMASK[n]
R/W-0
LEGEND: R/W = Read/Write; -n = value after reset
Table 22-25. Receive Format Unit Bit Mask Register (RMASK) Field Descriptions
Bit
Field
Value
Description
31-0
RMASK[31-0]
Receive data mask n enable bit.
0
Corresponding bit of receive data (after passing through reverse and rotate units) is masked out
and then padded with the selected bit pad value (RPAD and RPBIT bits in RFMT).
1
Corresponding bit of receive data (after passing through reverse and rotate units) is returned to
CPU or DMA.