Adeunis RF COMFORT LwM2M Скачать руководство пользователя страница 1

User Guide | COMFORT LwM2M | NB-IoT / LTE-Cat-M1

1

User Guide | COMFORT LwM2M | NB-
IoT / LTE-Cat-M1

Published

Category

Document version

V1.0.0

Language

EN

Type

Product/Service

Etat

Terminé

PRODUCT INFORMATION AND REGULATORY 
INFORMATION

💡

This User Guide applies to the following product:

COMFORT  
Reference :
 ARF8394AA 
APP Version: V1.2

INFORMATIONS DOCUMENT

Title

COMFORT LwM2M - User Guide

Type

User Guide

Version

1.0.0

Содержание COMFORT LwM2M

Страница 1: ...tegory Document version V1 0 0 Language EN Type Product Service Etat Termin PRODUCT INFORMATION AND REGULATORY INFORMATION This User Guide applies to the following product COMFORT Reference ARF8394AA...

Страница 2: ...n 1 2 Features 1 3 Package contents 1 4 Casing presentation 1 5 Dimensions 1 6 Push button 1 7 LEDs indicator 1 8 Power supply 1 8 1 Power source 1 8 2 Low Battery Management 1 8 3 Changing the double...

Страница 3: ...ion of Server Related Parameters 5 1 1 Using a Bootstrap Service to Register the Product 5 1 2 Registering the Product on an LwM2M Server without Using a Bootstrap Service 5 2 Configuration of Cellula...

Страница 4: ...osts strengthen sensor fleet security and optimize product battery life The product operates autonomously and intermittently It measures temperature and humidity data from the onboard sensors in sleep...

Страница 5: ...ommand sending configuration read write firmware update Multi Platform Integration Product data format standardization LwM2M that IoT platforms can interpret without the need for specific development...

Страница 6: ...e Queuing Telemetry Transport communication protocol To use the product with the MQTT protocol refer to the dedicated User Guide 1 3 Package contents The product is delivered in a cardboard packaging...

Страница 7: ...User Guide COMFORT LwM2M NB IoT LTE Cat M1 7 1 5 Dimensions Values in millimeters...

Страница 8: ...OFF OFF OFF Low battery level Flashing 500 ms ON 500 ms OFF every 1 min OFF OFF 1 8 Power supply 1 8 1 Power source The COMFORT can be powered by a double pack of FANSO Li SOCl2 ER18505H 2 batteries o...

Страница 9: ...minute it notifies the user that the battery level is low 1 8 2 2 User information The user can be informed of the product s battery status either locally through the NFC IoT Configurator application...

Страница 10: ...I Object name Resource Name Access type Unit Description 3 0 11 Device Error code R 0 No error 1 Low battery 1 8 3 Changing the double battery pack When the low battery indicator is activated it is po...

Страница 11: ...amaging the enclosure 2 Remove the current battery and replace it with the new one making sure to observe the polarity indicated on the electronic board and the battery model 3 To close the enclosure...

Страница 12: ...matically resume its normal operation and clear the low battery indicators status and LED 1 8 4 Connecting the external power supply 1 Insert a flathead screwdriver tilted towards the front of the enc...

Страница 13: ...TE Cat M1 13 CAUTION Press gently to avoid damaging the enclosure 2 Connect the external power supply using the dedicated connector 3 To close the enclosure insert the bottom of the front panel first...

Страница 14: ...6700 mA Operating conditions Recommended operating range 0 C to 50 C when powered by a double pack pile 0 C to 40 C when powered by an external power supply Operating temperature range 10 C to 70 C 2...

Страница 15: ...ssion Every Hour OBSERVE Mode 1 value of Temperature Humidity 1240 ko 320 ko Default configuration of the product in OBSERVE mode 1 measurement transmission per hour OBSERVE Mode reliable notification...

Страница 16: ...rmware and modem firmware FOTA 2 5 Integrated sensor specifications Specifications Value Temperature Technology CMOSens Recommended Operating Range 0 C 65 C Accuracy 0 2 C typ 1 C max Typical Resoluti...

Страница 17: ...of OBSERVATIONS in the case of using OBSERVE mode 3 1 Battery Life Estimates in OBSERVE Mode 3 1 1 NB IoT Network The two battery life tables below have been estimated based on a product configured t...

Страница 18: ...rage of 1 year before use calculations performed at an indoor temperature of 25 C They do not represent any commitment on the part of Adeunis The battery life depends on numerous non predictive networ...

Страница 19: ...0 minutes Every 10 minutes 7 8 3 6 Every 10 minutes Every hour historization 15 15 Every hour default product configuration Every hour default product configuration 15 15 Every hour Every 6 hours hist...

Страница 20: ...ta is transmitted the product returns to a low power consumption state The user can configure the following PSM parameters via the NFC IoT Configurator application The period during which the product...

Страница 21: ...ed does not allow access to PSM mode 4 PRODUCT SETUP 4 1 NFC IoT Configurator App NFC IoT Configurator is an Android application for mobile tablet that allows configuring the network server and applic...

Страница 22: ...onto other products NOTE 1 The use of the NFC antenna has an impact on the product s battery life To preserve battery autonomy it is preferable to only bring the smartphone close to the NFC antenna o...

Страница 23: ...tor application 4 2 2 PRODUCTION Mode This mode allows the product to function in its final use The NFC interface of the product is active to allow the user to read and modify the product s configurat...

Страница 24: ...ing down 7 Close the metal cover and slide it to the LOCK position 8 Place the electronic card back into the front face of the casing 3 Close the casing CAUTION Make sure the product is in PARK mode w...

Страница 25: ...ampling Frequency 3600 sec Transmission Frequency 3600 sec Temporary Emission Suspension blackout Disabled Alarm Mode for High and or Low Threshold Detection for Temperature Humidity Disabled LEDs Ope...

Страница 26: ...modes of the product the user must have previously configured the server and network parameters of the product using the NFC IoT Configurator application Refer to the following sections of this User G...

Страница 27: ...ED then flashes rapidly during the mode change phase rapid blinking of 5 cycles with 100 ms ON 100 ms OFF In case of a faulty product the red LED will light up for 15 seconds and then the product will...

Страница 28: ...nfigurator app As long as the product has not been attached to the network at least once for each failed attachment attempt the red LED will stay on for 5 seconds 4 6 1 2 Manual Network Attachment Onc...

Страница 29: ...Network Quality Verification Adeunis recommends that the installer check the network coverage level before installing the product in its final location 4 7 1 Verification via NFC IoT Configurator app...

Страница 30: ...ower every time it wakes up from sleep mode The installer user can check this network quality information at any time using the NFC IoT Configurator application or the server They can potentially relo...

Страница 31: ...allows products to securely and automatically retrieve their PSK encryption keys without human intervention ATTENTION Some LwM2M server providers may require the use of a bootstrap LwM2M server 5 1 1...

Страница 32: ...C IoT Configurator application go to the CONFIGURATION menu Then select the LwM2M CONFIGURATION section Apply the new configuration to the product via NFC 5 1 2 Registering the Product on an LwM2M Ser...

Страница 33: ...in order to transmit its data to an LwM2M server The following table lists all the network parameters of the COMFORT product and their default values Parameters Description Default Configuration Netwo...

Страница 34: ...ltiplier for the T3412 timer 6 hours T3324 Value Timer indicating the period during which the sensor remains reachable by the network after a transmission When the T3324 timer expires the product ente...

Страница 35: ...ration through a WRITE operation that changes the value of the PUSH period resource URI Object Name Resource Name Access Type Unit Description 34450 0 0 COMFORT PUSH period R W 0 STANDARD mode 1 PUSH...

Страница 36: ...s CONFIGURATION menu Select the APPLICATION section Configure the Sensor Sampling Frequency parameter Apply the new configuration to the product using NFC Configuration of the sampling interval via un...

Страница 37: ...ject instances and resources OIR Other transmission modes of the product are also possible such as emission on threshold exceedance periodic emission and emission on threshold exceedance These transmi...

Страница 38: ...loss in a degraded network quality context the user can enable the reliable notifications option This option ensures that notifications are properly received by the LwM2M server Note Enabling this op...

Страница 39: ...d to all 2 onboard sensors I want to be able to archive data from the onboard sensors I want to define a period for disabling the main functions to optimize the product s autonomy I want to manage ala...

Страница 40: ...600 seconds for the default configuration 5 3 2 2 Transmission Mode Configuration The COMFORT product can measure temperature humidity in a room and transmit the information using three emission modes...

Страница 41: ...tion is met trigger an action independently for temperature humidity data These rules can be used to limit the number of transmissions made by the COMFORT product and increase its lifespan The availab...

Страница 42: ...e humidity sensor measurement when a threshold is reached and when it returns to normal Disabled To configure thresholds using the NFC IoT Configurator app go to the CONFIGURATION menu Then select the...

Страница 43: ...eriod of the main functions and Blackout Start Time Apply the new configuration to the product via NFC Configuring a blackout period via an LwM2M server URI Object Name Resource Name Access Type Unit...

Страница 44: ...motely fix any potential bugs The user needs to contact the Adeunis support team to obtain the firmware update file s and use an LwM2M server to download the firmware to the COMFORT product using the...

Страница 45: ...pdate file to the product Step 3 The user can be notified of the progress of the update file download to the product at any time by performing a READ operation on the State resource of the standard Fi...

Страница 46: ...ing the sun or near a heat source cold source ventilation or in an airflow Maintain a minimum distance of one meter from doors or windows When installed on furniture avoid placing it in direct proximi...

Страница 47: ...ROTOCOL The COMFORT product can be configured to use one of the following two protocols to exchange data with an IoT platform MQTT or LwM2M Adeunis recommends the use of the LwM2M protocol as it is th...

Страница 48: ...models For more information about this protocol visit the website http www openmobilealliance org iot lightweight m2m lwm2m LwM2M Features Supported by the COMFORT Product and Limitations The COMFORT...

Страница 49: ...dity as well as for managing network parameters and product related parameters Object name ID Number of instances Object URN LwM2M Server 1 1 urn oma lwm2m oma 1 Device 3 1 urn oma lwm2m oma 3 Connect...

Страница 50: ...be supported URN urn oma lwm2m oma ext x Object ID Resource Format ID Numeric identifier of the resource Resource Name Brief description of the resource Operation R read only Resource W write only Re...

Страница 51: ...value of temperature humidity Block Diagram The single transmission is performed according to the following block diagram Read a Value READ Operation The server can request the product to return the c...

Страница 52: ...ampling period resource and the transmission period is determined by the value of the lifetime resource ANNEX 4 PERIODIC TRANSMISSION IN OBSERVE MODE The product allows for periodic retrieval of tempe...

Страница 53: ...tion on the sensor sampling period resource URI Object Name Resource Name Description Possible Configuration 34450 0 2 COMFORT Sensor sampling period Sampling period of temperature humidity between 60...

Страница 54: ...ch as minimum evaluation period epmin and maximum evaluation period epmax in an OBSERVE operation will not be considered by the product Example The LwM2M server requests the product to Retrieve temper...

Страница 55: ...3 0 Sensor value Humidity monitoring COMFORT 3304 0 Sensor value ANNEX 5 PERIODIC TRANSMISSION IN PUSH MODE The product allows for periodically retrieving temperature humidity and sending this informa...

Страница 56: ...ta transmissions to the server Disabled PUSH Mode Transmission Frequency Data transmission frequency in PUSH mode 3600 seconds Sensor Sampling Frequency Common scanning frequency for sensors 3600 Thes...

Страница 57: ...r hour T H Sensor Sampling Frequency Seconds 600 1 sample every 10 minutes T H Configuration via the NFC IoT Configurator App Go to the CONFIGURATION menu of the sensor Select the CONNECTIVITY section...

Страница 58: ...e product allows for periodic measurement of temperature humidity If the product detects a threshold exceeding high and or low it sends a notification to the server to alert the user A new notificatio...

Страница 59: ...User Guide COMFORT LwM2M NB IoT LTE Cat M1 59...

Страница 60: ...These parameters can be configured via the NFC IoT Configurator application or the LwM2M server Example The product measures temperature humidity every 10 minutes Alarms are configured for the produc...

Страница 61: ...transmission period to 0 seconds Go to the TEMPERATURE section Enable the high and low threshold alarm mode Configure the high threshold detection to 25 C the low threshold detection to 19 C and the h...

Страница 62: ...s this information to a server at regular intervals With the history mechanism if the sensor sampling frequency is higher than the transmission frequency the product will store all measured values in...

Страница 63: ...n PUSH Mode If this mode is enabled the product controls the data transmissions to the server Disabled PUSH Mode Transmission Frequency Frequency of data transmission in PUSH mode 3600 seconds Sensor...

Страница 64: ...ssion period After sending an alarm message the periodic transmission timer is reset meaning that the next periodic transmission will be sent at t PUSH mode transmission period These parameters can be...

Страница 65: ...tion Go to the Protocol subsection Configure the Product Server Communication parameter in PUSH mode Go to the APPLICATIVE section Configure the sensor sampling frequency to 1800 seconds Configure the...

Страница 66: ...er perform periodic transmissions This blackout period is configurable only in PUSH mode The table below lists the parameters to configure in order to define a blackout period rameters Description Def...

Страница 67: ...7 05 AM Configuration of Applicative Parameters to Use meters Unit Value Description PUSH Mode Enabled PUSH Mode Transmission Frequency Seconds 14400 1 transmission every 4 hours T H Sensor Sampling...

Страница 68: ...LwM2M NB IoT LTE Cat M1 68 Configuration via a LwM2M server URI Object Name Resource Name Access Type Unit Description 34450 0 3 COMFORT Blackout start time R W Hours 20 34450 0 4 COMFORT Blackout dur...