User Guide | COMFORT LwM2M | NB-IoT / LTE-Cat-M1
34
Parameters
Description
Default Configuration
Delay between 2 Network
Attachment Attempts
Delay between 2 consecutive
network attachment attempt
12 hours
APN
pecifies the Access Point Name
that determines the product's
connection settings to the internet
(network and operator)
-
T3412 Value
Timer defining the period for
periodic Transmission Area
Update (TAU) signal emission to
the network When the T3412 timer
expires, the product exits a deep
sleep state with no radio activity
(PSM cycle) The value of T3412
will be multiplied by its multiplier to
obtain the Keep-alive duration
1
T3412 Multiplier
Multiplier for the T3412 timer
6 hours
T3324 Value
Timer indicating the period during
which the sensor remains
reachable by the network after a
transmission When the T3324
timer expires, the product enters
PSM mode but remains registered
on the network The value of the
T3324 timer will be multiplied by its
multiplier to obtain the Active-time
duration
5
T3324 Multiplier
Multiplier for the T3324 timer
2 seconds
📱
If desired, the user can modify the default cellular network connection parameters in
the product using the NFC IoT Configurator application:
Go to the "CONFIGURATION" menu of the sensor => Select the "NETWORK" section =>
Configure the product => Apply the new configuration to the product via NFC.