Power, Reset, and Clock Management
8.1.13.1.4 PRM_IRQSTATUS_M3 Register (offset = Ch) [reset = 0h]
PRM_IRQSTATUS_M3 is shown in
and described in
This register provides status on MPU interrupt events. An event is logged whether interrupt generation for
the event is enabled or not. SW is required to clear a set bit by writing a '1' into the bit-position to be
cleared.
Figure 8-167. PRM_IRQSTATUS_M3 Register
31
30
29
28
27
26
25
24
Reserved
R-0h
23
22
21
20
19
18
17
16
Reserved
R-0h
15
14
13
12
11
10
9
8
dpll_per_recal_st
dpll_ddr_recal_st
dpll_disp_recal_st
dpll_core_recal_st
dpll_mpu_recal_st
ForceWkup_st
Reserved
Transition_st
R/W-0h
R/W-0h
R/W-0h
R/W-0h
R/W-0h
R/W-0h
R-0h
R/W-0h
7
6
5
4
3
2
1
0
Reserved
R-0h
LEGEND: R/W = Read/Write; R = Read only; W1toCl = Write 1 to clear bit; -n = value after reset
Table 8-182. PRM_IRQSTATUS_M3 Register Field Descriptions
Bit
Field
Type
Reset
Description
31-16
Reserved
R
0h
15
dpll_per_recal_st
R/W
0h
interrupt status for usb dpll recaliberation
0 = DIS : Disables dpll recaliberation
1 = EN : ENAbles dpll recaliberation
14
dpll_ddr_recal_st
R/W
0h
interrupt status for ddr dpll recaliberation
0 = DIS : Disables dpll recaliberation
1 = EN : ENAbles dpll recaliberation
13
dpll_disp_recal_st
R/W
0h
interrupt status for disp dpll recaliberation
0 = DIS : Disables dpll recaliberation
1 = EN : ENAbles dpll recaliberation
12
dpll_core_recal_st
R/W
0h
interrupt status for core dpll recaliberation
0 = DIS : Disables dpll recaliberation
1 = EN : ENAbles dpll recaliberation
11
dpll_mpu_recal_st
R/W
0h
interrupt status for mpu dpll recaliberation
0 = DIS : Disables dpll recaliberation
1 = EN : ENAbles dpll recaliberation
10
ForceWkup_st
R/W
0h
Software supervised wakeup completed event interrupt status
0 = IRQ_fal : No interrupt
1 = IRQ_tru : Interrupt is pending
9
Reserved
R
0h
8
Transition_st
R/W
0h
Software supervised transition completed event interrupt status (any
domain)
0 = IRQ_fal : No interrupt
1 = IRQ_tru : Interrupt is pending
7-0
Reserved
R
0h
709
SPRUH73H – October 2011 – Revised April 2013
Power, Reset, and Clock Management (PRCM)