Air Conditioning System: Manual Type 7B-8
No cool air comes out
(Blower motor does not
operate)
Fuse blown
Check related fuses and short circuit to
ground.
Blower motor controller faulty
Check blower motor resistor referring to
“Blower Motor Controller Inspection in Section
7A”.
Blower speed selector faulty
Check blower speed selector referring to
“Inspection of HVAC Control Module and its
Circuit”.
Wiring or grounding faulty
Check wiring and grounding.
Blower motor faulty
Check blower motor referring to “Blower Motor
Inspection in Section 7A”.
Blower motor relay faulty
Check blower motor relay referring to “Blower
Motor Relay Inspection in Section 7A”.
HVAC control module and/or its circuit
faulty
Check HVAC control module and its circuit
referring to “Inspection of HVAC Control
Module and its Circuit”.
Cool air does not come
out or insufficient cooling
(A/C system operates
normally)
Insufficient or excessive charge of
refrigerant
Check amount of refrigerant charged and
system for leaks.
Condenser clogged
Check condenser referring to “Condenser
Assembly Inspection”.
A/C evaporator clogged or frosted
Check A/C evaporator and A/C evaporator
outlet temperature sensor referring to “A/C
Evaporator Inspection” and “A/C Evaporator
Inlet and Outlet Air Temperature Sensors
Inspection”.
A/C evaporator inlet and/or outlet air
temperature sensor faulty
Check A/C evaporator inlet and/or outlet
temperature sensor referring to “A/C
Evaporator Inlet and Outlet Air Temperature
Sensors Inspection”.
Expansion valve faulty
Check expansion valve referring to “Expansion
Valve Inspection”.
Desiccant clogged
Check desiccant.
Compressor drive belt loosen or broken
Replace compressor drive belt.
Magnetic clutch faulty
Check magnetic clutch referring to
“Compressor Inspection”.
Compressor faulty
Check compressor.
Air in A/C system
Replace desiccant, and perform evacuation
and charging.
Air leaking from heater and cooling unit
or air duct
Repair as necessary.
Heater and ventilation system faulty
Repair as necessary.
Blower motor faulty
Check blower motor referring to “Blower Motor
Inspection in Section 7A”.
Excessive compressor oil existing in A/C
system
Pull out excessive compressor oil in A/C
system circuit, and check compressor.
Cool air does not come
out only intermittently
Wiring connection faulty
Repair as necessary.
Expansion valve faulty
Check expansion valve referring to “Expansion
Valve Inspection”.
Excessive moisture in A/C system
Replace desiccant, and perform evacuation
and charging.
Magnet clutch faulty
Check magnetic clutch referring to
“Compressor Inspection”.
Excessive charge of refrigerant
Check charge of refrigerant.
Condition
Possible cause
Correction / Reference Item
Содержание Liana RH413
Страница 2: ......
Страница 4: ......
Страница 6: ......
Страница 58: ...1A 7 Engine General Information and Diagnosis Engine and Emission Control System Flow Diagram I2RH0B110006 01...
Страница 336: ...1K 4 Exhaust System...
Страница 456: ...3D 4 Propeller Shafts...
Страница 553: ...Automatic Transmission Transaxle 5A 5 4WD I3RH0A510002 01 1 Transfer...
Страница 648: ...5A 100 Automatic Transmission Transaxle Automatic Transaxle Assembly Components S3RH0A5106025 I3RH0A510027 01...
Страница 1044: ...8B 119 Air Bag System...
Страница 1049: ...Table of Contents 9 v Roof Molding Components 9M 1 Splash Guard If Equipped Components 9M 2...
Страница 1085: ...Wiring Systems 9A 35 8 9 17 18 21 FWD R 5door 4door 5door 23 FWD L 6 7 7 2 FWD L Left side shown 13 10 14 L R I3RH0A910975 01...
Страница 1274: ...9L 14 Paint Coatings Wagon Under Coating Application Areas S3RH0A9C23002 Refer to Under Coating Application Areas...
Страница 1278: ...9M 3 Exterior Trim...
Страница 1300: ...Prepared by 1st Ed Nov 2003 2nd Ed Feb 2007...
Страница 1301: ...19 mm 99500 54G10 01E 99500 54G10 01E SERVICE MANUAL VOLUME 1 OF 2 SERVICE MANUAL VOL 1 OF 2...
Страница 1302: ...27 mm 99500 54G10 01E 99500 54G10 01E SERVICE MANUAL VOLUME 2 OF 2 SERVICE MANUAL VOL 2 OF 2...