1J-4 Charging System:
Generator Symptom Diagnosis
S3RH0A1A04002
CAUTION
!
• Do not mistake polarities of “IG” terminal
and “L” terminal.
• Do not create short circuit between “IG”
and “L” terminals. Always connect these
terminals through a lamp.
• Do not connect any load between “L” and
“E” terminals.
• When connecting charger or booster
battery to vehicle battery, refer to “Jump
Starting in Case of Emergency”.
Trouble in charging system will show up as one or more
of the following conditions:
1) Faulty indicator lamp operation.
2) An undercharged battery as evidenced by slow
cranking or indicator dark.
3) An overcharged battery as evidenced by excessive
spewing of electrolyte from vents.
Noise from generator may be caused by loose drive
pulley, loose mounting bolts, worn or dirty bearings,
defective diode, or defective stator.
Charging Indicator Lamp Operation
Generator Test (Undercharged Battery Check)
S3RH0A1A04003
This condition, as evidenced by slow cranking or low
specific gravity can be caused by one or more of the
following conditions even though indicator lamp may be
operating normal. The following procedure also applies
to cars with voltmeter and ammeter.
• Make sure that undercharged condition has not been
caused by accessories left on for extended period of
time.
• Check drive belt for proper tension.
• If battery defect is suspected, refer to “Battery
• Inspect wiring for defects. Check all connections for
tightness and cleanliness, battery cable connections
at battery, starting motor and ignition ground cable.
No-Load Check
1) Connect voltmeter and ammeter as shown in the
figure.
NOTE
Use fully charged battery.
B: Generator output (Battery terminal)
F: Field coil terminal
C: C terminal
IG: Ignition terminal
E: Ground
L: Lamp terminal
I2RH0B1A0004-01
Condition
Possible cause
Correction / Reference Item
Charge light does not
light with ignition ON and
engine off
Fuse blown
Check fuse.
Indicator lamp (LED) faulty
Replace combination meter.
Wiring connection loose
Tighten loose connection.
IC regulator or field coil faulty
Check generator.
Poor contact between brush and slip
ring
Repair or replace.
Charge light does not go
out with engine running
(battery requires frequent
recharging)
Drive belt loose or worn
Adjust or replace drive belt.
IC regulator or generator faulty
Check charging system.
Wiring faulty
Repair wiring.
1. Generator
2. Ammeter (between generator “B” terminal and battery (+) terminal)
3. Voltmeter (between generator “B” terminal and ground)
4. Battery
5. Load
6. Switch
I2RH011A0006-01
Содержание Liana RH413
Страница 2: ......
Страница 4: ......
Страница 6: ......
Страница 58: ...1A 7 Engine General Information and Diagnosis Engine and Emission Control System Flow Diagram I2RH0B110006 01...
Страница 336: ...1K 4 Exhaust System...
Страница 456: ...3D 4 Propeller Shafts...
Страница 553: ...Automatic Transmission Transaxle 5A 5 4WD I3RH0A510002 01 1 Transfer...
Страница 648: ...5A 100 Automatic Transmission Transaxle Automatic Transaxle Assembly Components S3RH0A5106025 I3RH0A510027 01...
Страница 1044: ...8B 119 Air Bag System...
Страница 1049: ...Table of Contents 9 v Roof Molding Components 9M 1 Splash Guard If Equipped Components 9M 2...
Страница 1085: ...Wiring Systems 9A 35 8 9 17 18 21 FWD R 5door 4door 5door 23 FWD L 6 7 7 2 FWD L Left side shown 13 10 14 L R I3RH0A910975 01...
Страница 1274: ...9L 14 Paint Coatings Wagon Under Coating Application Areas S3RH0A9C23002 Refer to Under Coating Application Areas...
Страница 1278: ...9M 3 Exterior Trim...
Страница 1300: ...Prepared by 1st Ed Nov 2003 2nd Ed Feb 2007...
Страница 1301: ...19 mm 99500 54G10 01E 99500 54G10 01E SERVICE MANUAL VOLUME 1 OF 2 SERVICE MANUAL VOL 1 OF 2...
Страница 1302: ...27 mm 99500 54G10 01E 99500 54G10 01E SERVICE MANUAL VOLUME 2 OF 2 SERVICE MANUAL VOL 2 OF 2...