Heater and Ventilation: 7A-9
Fail-Safe Table
S3RH0A7104005
When any of the following malfunctions (DTCs) is detected, HVAC control module enters fail-safe mode. However,
when HVAC control module detects normal operation of A/C system, fail-safe mode is canceled.
Scan Tool Data
S3RH0A7104006
As the data values given in the following are standard values estimated on the basis of values obtained from the
normally operation vehicles by using a scan tool, use them as reference values. Even when the vehicles are in good
condition, there may be cases where the checked values do not fall within each specifies data range. Therefore,
judgement as abnormal should not be made by checking with these data alone.
DTC
No.
Trouble Area
Fail-Safe Operation
Detection of malfunction when
ignition switch is turned ON
Detection of malfunction during
ignition switch is ON
B1511
Temperature control actuator
(position sensor) and/or its circuit
The operation of actuator stops.
B1512
Air flow control actuator (position
sensor) and/or its circuit
B1513
Temperature control actuator and/
or its circuit
B1514
Air flow control actuator and/or its
circuit
B1520
Temperature selector and/or its
circuit
Middle position
B1521
Blower speed selector and/or its
circuit
1st position
B1522
Air flow selector and/or its circuit
DEF position
Scan Tool Data
Condition
Normal Condition / Reference Value
TEMP CONT SWITCH
Each reference value is relative to the position of
temperature selector of HVAC control module.
Max Cool, P1, P2 – P20, P21, Max Hot
MODE CONT SWITCH
Each reference value is relative to the position of air
flow selector of HVAC control module.
VENT, BI-LEVEL, FOOT, DEF-FOOT,
DEF
FAN CONT SWITCH
Each reference value is relative to the position of
blower speed selector of HVAC control module.
OFF, 1st, 2nd – 7th, 8th
FAN DESIRE VOLT
Reference value is relative to the position of blower
speed selector of HVAC control module.
0 – 15.5 V
AIR MIX POS SENSOR
Reference value is relative to the position of
temperature selector of HVAC control module.
about 1.0 V (Max Hot)
about 4.0 V (Max Cool)
MODE POS SENSOR
Reference value is relative to the position of airflow
selector of HVAC control module.
about 1.0 V (DEF)
about 4.0 V (VENT)
BLOWER FAN LOAD
Position of blower speed selector is 1st or 2nd
position.
ON
Position of blower speed selector is more than 3rd
position.
OFF
AIR INTAKE MODE
Fresh air (FRE) mode is activated.
FRE
Recirculation air (REC) mode is activated.
REC
REC INDICATOR
LAMP
Recirculation air (REC) indicator lamp is lighted.
ON
Recirculation air (REC) indicator lamp is not lighted.
OFF
FRE INDICATOR LAMP
Fresh air (FRE) indicator lamp is lighted
ON
Fresh air (FRE) indicator lamp is not lighted
OFF
REAR DEF INDICATOR
LAMP
Rear defogger indicator lamp is lighted
ON
Rear defogger indicator lamp is not lighted
OFF
Содержание Liana RH413
Страница 2: ......
Страница 4: ......
Страница 6: ......
Страница 58: ...1A 7 Engine General Information and Diagnosis Engine and Emission Control System Flow Diagram I2RH0B110006 01...
Страница 336: ...1K 4 Exhaust System...
Страница 456: ...3D 4 Propeller Shafts...
Страница 553: ...Automatic Transmission Transaxle 5A 5 4WD I3RH0A510002 01 1 Transfer...
Страница 648: ...5A 100 Automatic Transmission Transaxle Automatic Transaxle Assembly Components S3RH0A5106025 I3RH0A510027 01...
Страница 1044: ...8B 119 Air Bag System...
Страница 1049: ...Table of Contents 9 v Roof Molding Components 9M 1 Splash Guard If Equipped Components 9M 2...
Страница 1085: ...Wiring Systems 9A 35 8 9 17 18 21 FWD R 5door 4door 5door 23 FWD L 6 7 7 2 FWD L Left side shown 13 10 14 L R I3RH0A910975 01...
Страница 1274: ...9L 14 Paint Coatings Wagon Under Coating Application Areas S3RH0A9C23002 Refer to Under Coating Application Areas...
Страница 1278: ...9M 3 Exterior Trim...
Страница 1300: ...Prepared by 1st Ed Nov 2003 2nd Ed Feb 2007...
Страница 1301: ...19 mm 99500 54G10 01E 99500 54G10 01E SERVICE MANUAL VOLUME 1 OF 2 SERVICE MANUAL VOL 1 OF 2...
Страница 1302: ...27 mm 99500 54G10 01E 99500 54G10 01E SERVICE MANUAL VOLUME 2 OF 2 SERVICE MANUAL VOL 2 OF 2...