7B-65 Air Conditioning System: Automatic Type
DTC B1514 (No.14): Air Flow Control Actuator and/or its Circuit malfunction
S3RH0A7224019
Wiring Diagram
DTC Detecting Condition and Trouble Area
DTC Troubleshooting
NOTE
First, perform “Air flow control actuator motor circuit inspection: Automatic Type”. After that, if DTC
1514 is still detected, perform “Air flow control actuator position sensor circuit inspection: Automatic
Type”.
Air flow control actuator motor circuit inspection
M
12V
5V
5V
RED/WHT
WHT/BLU
BLK/RED
GRY/RED
GRY/BLK
G77-9
G77-12
G77-26
G77-18
G77-17
2
1
3
9
12
26
17
18
I3RH0A722016-01
1. HVAC control module
2. Air flow control actuator
3. HVAC control module connector “G77” (viewed from harness side)
DTC Detecting Condition
Trouble Area
• Signal from air flow control position sensor is less than the specified (3.4
V) in operation to FACE direction after 15 seconds.
• Signal from air flow control position sensor is more than the specified (1.6
V) in operation to DEF direction after 15 seconds.
• “GRY/RED”, “GRY/BLK”, “RED/
WHT”, “WHT/BLU” and/or “BLK/
RED” wire faulty
• Linkage faulty
• Heater and cooling unit faulty
• Air flow control actuator faulty
• HVAC control module faulty
Step
Action
Yes
No
1
1) Check if there is any obstruction in operating range of
actuator linkage and if actuator linkage operates
smoothly.
Is there any obstruction? Does actuator linkage operate
smoothly?
Obstruction in operating
range of actuator
linkage, actuator linkage
faulty, and/or internal
fault of heater and
cooling unit.
Go to Step 2.
2
1) Turn ignition switch OFF, and then disconnect air flow
control actuator connector referring to “Air Flow Control
Actuator Removal and Installation in Section 7A”.
2) Turn ignition switch ON, and then check voltage
between “GRY/RED” wire terminal at air flow control
actuator connector and body ground.
Is voltage about 12 V?
Go to Step 5.
Go to Step 3.
3
1) Turn ignition switch OFF, and then disconnect HVAC
control module connector referring to “HVAC Control
Module Removal and Installation in Section 7A”.
2) Check resistance between “GRY/RED” wire terminal at
air flow control actuator connector and “GRY/RED” wire
terminal at HVAC control module connector.
Is resistance less than 1 M
Ω
?
Go to Step 4.
“GRY/RED” wire open
or high resistance.
Содержание Liana RH413
Страница 2: ......
Страница 4: ......
Страница 6: ......
Страница 58: ...1A 7 Engine General Information and Diagnosis Engine and Emission Control System Flow Diagram I2RH0B110006 01...
Страница 336: ...1K 4 Exhaust System...
Страница 456: ...3D 4 Propeller Shafts...
Страница 553: ...Automatic Transmission Transaxle 5A 5 4WD I3RH0A510002 01 1 Transfer...
Страница 648: ...5A 100 Automatic Transmission Transaxle Automatic Transaxle Assembly Components S3RH0A5106025 I3RH0A510027 01...
Страница 1044: ...8B 119 Air Bag System...
Страница 1049: ...Table of Contents 9 v Roof Molding Components 9M 1 Splash Guard If Equipped Components 9M 2...
Страница 1085: ...Wiring Systems 9A 35 8 9 17 18 21 FWD R 5door 4door 5door 23 FWD L 6 7 7 2 FWD L Left side shown 13 10 14 L R I3RH0A910975 01...
Страница 1274: ...9L 14 Paint Coatings Wagon Under Coating Application Areas S3RH0A9C23002 Refer to Under Coating Application Areas...
Страница 1278: ...9M 3 Exterior Trim...
Страница 1300: ...Prepared by 1st Ed Nov 2003 2nd Ed Feb 2007...
Страница 1301: ...19 mm 99500 54G10 01E 99500 54G10 01E SERVICE MANUAL VOLUME 1 OF 2 SERVICE MANUAL VOL 1 OF 2...
Страница 1302: ...27 mm 99500 54G10 01E 99500 54G10 01E SERVICE MANUAL VOLUME 2 OF 2 SERVICE MANUAL VOL 2 OF 2...