Operation
6.10 Communication via SINAMICS Link
Enclosed Drives
Operating Instructions, 12/2018, A5E36652151A
391
Features
●
The CBE20 can be assigned to IF1 or IF2 when SINAMICS Link is used.
The interface, assigned to the CBE20, must be switched into synchronous operation if
p8812[0] = 1 is set.
You must also make the following parameter settings in order to assign, e.g. IF1 to
SINAMICS Link:
–
For IF1: p8839[0] = 2 (COMM BOARD)
–
For IF2: p8839[1] = 1 (Control Unit onboard)
The following data is applicable for the case (IF1
≙
SINAMICS Link):
●
The number of the respective node must be entered manually in parameter p8836.
A different number must be assigned for each node.
Enter the numbers is ascending order, starting with "1".
●
If p8836 is set to 0, the nodes and the complete following line is shut down for SINAMICS
Link.
●
Gaps in the numbering are not permitted, as then SINAMICS Link would not function.
●
The node with the number 1 is automatically the sync master of the communication link.
●
The ports of the CBE20 must be interconnected strictly in accordance with the above
diagram. You must always connect port 2 (P2) of node n with port 1 (P1) of node n + 1.
●
In the "SINAMICS Link" mode, ports 3 and 4 of the CBE20 can only be used in
conjunction with the STARTER commissioning tool.
Corresponding parameters for IF1 or IF2
Use different parameters for configuring, depending on which interface SINAMICS Link is
assigned:
Table 6- 33 Corresponding parameters for IF1 or IF2
Parameter
IF1
IF2
Setting of the processing mode for PROFIdrive STW1.10 "Control by PLC".
p2037
p8837
Connector output to interconnect the PZD (setpoints) received from the fieldbus controller
in the word format.
r2050
r8850
Selects the PZD (actual values) to be sent to the fieldbus controller in the word format.
p2051
p8851
Displays the PZD (actual values) sent to the fieldbus controller in the word format.
r2053
r8853
Connector output to interconnect the PZD (setpoints) received from the fieldbus controller
in the double word format.
r2060
r8860
Selects the PZD (actual values) to be sent to the fieldbus controller in the double word
format.
p2061
p8861
Displays the PZD (actual values) sent to the fieldbus controller in the double word format.
r2063
r8863
Содержание SINAMICS S150 NEMA
Страница 1: ......
Страница 2: ......
Страница 20: ...Table of contents Enclosed Drives 18 Operating Instructions 12 2018 A5E36652151A ...
Страница 42: ...Device overview 2 5 Rating plate Enclosed Drives 40 Operating Instructions 12 2018 A5E36652151A ...
Страница 200: ...Electrical installation 4 9 Additional connections Enclosed Drives 198 Operating Instructions 12 2018 A5E36652151A ...
Страница 500: ...Output terminals 8 3 Digital outputs Enclosed Drives 498 Operating Instructions 12 2018 A5E36652151A ...
Страница 828: ...Technical specifications 12 3 Technical specifications Enclosed Drives 826 Operating Instructions 12 2018 A5E36652151A ...
Страница 861: ......
Страница 862: ......