Error values in parameter responses
Table 6- 21 Error values in parameter responses
Error
value
Meaning
Comment
Additional
info
0x00
Illegal parameter number.
Access to a parameter that does not exist.
–
0x01
Parameter value cannot be changed. Modification access to a parameter value that cannot be
changed.
Subindex
0x02
Lower or upper value limit exceeded. Modification access with value outside value limits.
Subindex
0x03
Invalid subindex.
Access to a subindex that does not exist.
Subindex
0x04
No array.
Access with subindex to an unindexed parameter.
–
0x05
Wrong data type.
Modification access with a value that does not match the
data type of the parameter.
–
0x06
Illegal set operation (only reset
allowed)
Modification access with a value not equal to 0 in a case
where this is not allowed.
Subindex
0x07
Description element cannot be
changed
Modification access to a description element that cannot
be changed.
Subindex
0x09
No description data available
Access to a description that does not exist (the parameter
value exists).
–
0x10
Read job will not be executed.
The read request is refused because know-how protection
is active.
–
0x0B
No parameter change rights.
Modification access with no parameter change rights.
–
0x0F
No text array exists
Access to a text array that does not exist (the parameter
value exists).
–
0x11
Request cannot be executed due to
operating status.
Access is temporarily not possible for unspecified reasons. –
0x14
Illegal value.
Modification access with a value that is within the limits but
is illegal for other permanent reasons (parameter with
defined individual values).
Subindex
0x15
Response too long.
The length of the present response exceeds the maximum
transfer length.
–
0x16
Illegal parameter address.
Illegal or unsupported value for attribute, number of
elements, parameter number, subindex or a combination
of these.
–
0x17
Illegal format.
Write request: illegal or unsupported parameter data
format.
–
0x18
Number of values inconsistent.
Write request: a mismatch exists between the number of
values in the parameter data and the number of elements
in the parameter address.
–
0x19
Drive object does not exist.
You have attempted to access a drive object that does not
exist.
–
0x20
Parameter text cannot be changed.
–
–
0x21
Service is not supported.
Illegal or unknown request ID.
–
0x65
Parameter presently deactivated.
You have tried to access a parameter that, although
available, does not currently perform a function
(e.g., n control set and access to a V/f control parameter).
–
Содержание SINAMICS S150 NEMA
Страница 1: ......
Страница 2: ......
Страница 20: ...Table of contents Enclosed Drives 18 Operating Instructions 12 2018 A5E36652151A ...
Страница 42: ...Device overview 2 5 Rating plate Enclosed Drives 40 Operating Instructions 12 2018 A5E36652151A ...
Страница 200: ...Electrical installation 4 9 Additional connections Enclosed Drives 198 Operating Instructions 12 2018 A5E36652151A ...
Страница 500: ...Output terminals 8 3 Digital outputs Enclosed Drives 498 Operating Instructions 12 2018 A5E36652151A ...
Страница 828: ...Technical specifications 12 3 Technical specifications Enclosed Drives 826 Operating Instructions 12 2018 A5E36652151A ...
Страница 861: ......
Страница 862: ......