Functions, monitoring and protective functions
9.4 Extended functions
Enclosed Drives
670
Operating Instructions, 12/2018, A5E36652151A
Note
Flying referencing is not an active operating mode. It is superimposed by an active operating
mode.
In contrast to reference point approach, flying referencing can be carried out superimposed
by the machine process.
As standard, for flying referencing, measuring probe evaluation is used; when enabled, the
measuring probe is selected (p2510) and the edge evaluation (p2511) (in the factory setting,
measuring probe 1 is always the measuring probe, flank evaluation in the factory setting is
always the 0/1 edge).
Instructions for switching data sets
Using drive data set changeover (DDS), motor data sets (MDS, p0186) and encoder data
sets (EDS, p0187 to p0189) can be changed over. The following table shows when the
reference bit (r2684.11) or the status of the adjustment with absolute encoders (p2507) is
reset.
In the following cases, when a DDS changeover takes place, the actual position value
becomes invalid (p2521 = 0) and the reference point (r2684.11 = 0) is reset:
●
The encoder data set (EDS) that is effective for the position control changes.
●
The encoder assignment changes (p2502).
●
The mechanical conditions change (p2503 to p2506).
With absolute encoders, the status of the adjustment (p2507) is also reset, if the same
absolute encoder is selected for the position control although the mechanical conditions
have changed (p2503 to p2506).
In operating mode, a fault (F07494) is also output.
The following table contains a few examples for data set switching. The initial data set is
always DDS0.
Table 9- 18 DDS switch without load gear position tracking
DDS
0
1
2
3
4
5
6
7
p0186 (MDS)
0
0
0
0
0
1
2
3
p0187 (encoder 1)
EDS0
EDS0
EDS0
EDS0
EDS0
EDS4
EDS5
EDS0
p0188 (encoder 2)
EDS1
EDS1
EDS1
EDS1
EDS3
EDS1
EDS6
EDS1
p0189 (encoder 3)
EDS2
EDS2
EDS2
EDS2
EDS2
EDS2
EDS7
EDS2
p2502 (encoder for
position control)
Encod-
er_1
Encod-
er_1
Encoder_1
Encod-
er_2
Encod-
er_2
Encod-
er_1
Encod-
er_1
Encod-
er_1
Mechanical relation-
ships
p2504/p2505/p2506/
p2503
A, B and D designate
different mechanical
relationships.
A
A
B
A
A
A
D
A
Load gear position
tracking
Deac-
tivated
Deac-
tivated
Deactivated
Deac-
tivated
Deac-
tivated
Deac-
tivated
Deac-
tivated
Deac-
tivated
Содержание SINAMICS S150 NEMA
Страница 1: ......
Страница 2: ......
Страница 20: ...Table of contents Enclosed Drives 18 Operating Instructions 12 2018 A5E36652151A ...
Страница 42: ...Device overview 2 5 Rating plate Enclosed Drives 40 Operating Instructions 12 2018 A5E36652151A ...
Страница 200: ...Electrical installation 4 9 Additional connections Enclosed Drives 198 Operating Instructions 12 2018 A5E36652151A ...
Страница 500: ...Output terminals 8 3 Digital outputs Enclosed Drives 498 Operating Instructions 12 2018 A5E36652151A ...
Страница 828: ...Technical specifications 12 3 Technical specifications Enclosed Drives 826 Operating Instructions 12 2018 A5E36652151A ...
Страница 861: ......
Страница 862: ......