Commissioning
5.3 Procedure for commissioning with STARTER
Enclosed Drives
220
Operating Instructions, 12/2018, A5E36652151A
Configuring the motor – Selecting the type of connection
Figure 5-19 Configuring the motor – Selecting the type of connection
⇒
Under Connection type:, select whether the motor is connected in a star or delta
connection.
The values for the rated motor voltage (p0304) and rated motor current (p0305) are
automatically converted according on the selected connection type.
⇒
Click on Next > to configure the motor holding brake