SV800/SV800A User Manual 6 Function Parameters List
89
6.3 Function Parameters List
A0: Basic parameter group
No.
Name
Content
Set value
A0-00
(0000H)
Keyboard language selection
<1>
ALL
0: Chinese
1: English (reserved)
Factory default: 0
Range: 0~1
A0-01
(0001H)
User password setting
ALL
Factory default: 0
Range: 0~65535
A0-02
(0002H)
Parameters access level
ALL
0: Only for monitoring (A0-02 and monitoring group parameter
UX-XX)
1: Common parameters (Customer application parameters
A1-XX)
2: All parameters
3: Customer application mapped parameters
Factory default: 2
Range: 0~ 3
A0-04
(0004H)
Control mode setting
ALL
Induction motor:
0: Sensorless vector control (IM.SVC)
1: Close-loop vector control (IM.VC)
2: V/F control (IM.VF)
For more details, please refer to "5.5.3 Control Mode Settings
and Modifications"
Factory default: 2
Range: 0~ 2
A0-05
(0005H)
Carrier frequency setting <2>
ALL
The factory value determined by inverter type and generally not
need to adjust.
Note: In order to ensure the control accuracy, when changing the
carrier frequency during vector control, static self-learning must
be performed again. For details, refer to "5.3 Self-learning of
Induction Motors".
Factory default:
Depends on
inverter type
Range: 1.0~15.0
A0-06
(0006H)
Initialization
ALL
0: No parameters initialized
1:All parameters initialized
2: Application parameters initialized (excluding control mode,
carrier frequency, motor parameters group b1/b2, A1-00)<3>
Factory default: 0
Range: 0~6
A0-07
(0007H)
Parameters upload and
download
ALL
0: No action
1: Upload to keyboard
2: Download (Include motor parameters)
3: Download (Exclude motor parameters)
If the uploaded version is inconsistent with the downloaded
version of the control board program, CPy malfunction will be
displayed when using keyboard to download. Please set the
application parameters manually. The program version is
checked in parameters U0-23, U0-24, U0-25.
Factory default: 0
Range: 0~3