7 Detailed function description SV800/SV800A User Manual
196
No.
Name
Set range
Factory default
H4-05
Multi-function Pulse output HDO function
0
~
9
0
Please refer to Table 7-6 for specific Settings.
No.
Name
Set range
Factory default
H4-06
HDO output range setting
0.10KHz
~
100.00KHz
20.00KHz
Used to set the Max. pulse frequency of the highs peed pulse output terminal.
Table 7-6 Pulse output function
Set value
Function
Range
0
No function
1
The set speed command
0~ Upper limit speed/frequency
2
Motor speed
0~ Upper limit speed/frequency
3
Inverter output frequency
0~ Upper limit speed/frequency
4
Inverter output current
0~2 times motor rated current
5
Inverter output voltage
0~ motor rated voltage
6
DC bus voltage
0.0~1000.0V
7
Torque command
0%~300%
8
Input pulse frequency
0~H4-00
9
Motor output torque
0~Motor Max. output torque