![SCOV SV800 Series Скачать руководство пользователя страница 26](http://html.mh-extra.com/html/scov/sv800-series/sv800-series_user-manual_1219567026.webp)
2 Product Introduction SV800/SV800A User Manual
18
Control mode
Sensorless
vector control
(IM.SVC)
With sensor
vector control
(IM.VC)
V/F control
(IM.VF)
Remarks
Speed jump
Support
Support
Support
When the function is
enabled, the
acceleration/deceleration
interval will be traversed
according to the Acc./Dec.
time;
Under V/F control, it has t
over-frequency protection.
VF torque limit
-
-
Support
Under V/F control, the
torque limit function is
turned off by factory default.
If the function is needed,
please set parameters to
enable it.
VF automatic
torque boost
-
-
Support
Under V/F control, when the
function is valid, the torque
boost value will become
invalid.
VF oscillation
suppression
-
-
Support
Vector control not require
oscillation suppression.