6 Function Parameters List SV800/SV800A User Manual
96
d0 :Speed control debugging parameters
No.
Name
Content
Set value
d0-11
(300BH)
The trigger threshold of
variable structure control
parameters automatically
adjust
IM.SVC IM.VC
SVC control mode
factory default
:
5.00%
Range
:
0.01%~100.00%
VC control mode
factory default
:
0.01%
Range
:
0.01%~100.00%
d0-12
(300CH)
The Min. threshold of
variable structure control
parameters automatically
adjust
IM.SVC IM.VC
SVC control mode
factory default
:
20%
Range
:
0%~100%
VC control mode
factory default
:
100%
Range
:
0% ~100%
d0-13
(300DH)
Speed control
proportional gain 2
IM.SVC IM.VC
Factory default
:
15
Range
:
0~100
d0-14
(300EH)
Speed control
proportional gain
selection
IM.SVC IM.VC
0: The default speed control gain, depending on the selected
motor
1: The speed control proportional gain 2; Valid immediately
when Enabled
2: Special mode
Factory default
:
0
Range
: