SV800/SV800A User Manual 6 Function Parameters List
103
d4: V/F control mode parameters
No.
Name
Content
Set value
d4-12
(340CH)
VF curve frequency 1
IM.VF
Factory default
:
0.00Hz
Range
:
0.00Hz~[d4-14]
d4-13
(340DH)
VF curve voltage 2
IM.VF
Factory default
:
0V
Range
:
0V~460V
d4-14
(340EH)
VF curve frequency 2
IM.VF
Factory default
:
0.00Hz
Range
:
[d4-12]~[d4-16]
d4-15
(340FH)
VF curve voltage 3
IM.VF
Factory default
:
0V
Range
:
0V~460V
d4-16
(3410H)
VF curve frequency 3
IM.VF
Factory default
:
0.00Hz
Range
:
[d4-14]~[d4-18]
d4-17
(3411H)
VF curve t voltage 4
IM.VF
Factory default
:
0V
Range
:
0V~460V
d4-18
(3412H)
VF curve frequency 4
IM.VF
Max. value b1-05(First motor rated frequency) or b2-05
(Second motor rated frequency)
Factory default
:
0.00Hz
Range
:
[d4-16]
~[b1-05]
Note: <1>220V voltage level: 0~230V,400V voltage level: 0~460V
E0 : The upper and low limit speed/ frequency
No.
Name
Content
Set value
E0-00
(4000H)
Upper limit
speed/frequency
ALL
When A0-13=1 (0.01Hz resolution), the limit is 199.99Hz;
When A0-13=0 (0.1Hz resolution), the limit is 400.0Hz;
Set A0-13=2 (1r/Minimum resolution), the limit is 14700r/min.
Set upper limit frequency according to the application
conditions
Factory default
:
50.00Hz
Range
:
E0-01~199.99Hz
E0-01
(4001H)
Low limit
speed/frequency
ALL
Set the low limit frequency according to the application
conditions
Factory default
:
0.00Hz
Range
:
E0-03~E0-00
E0-02
(
4002H
)
Max. speed/frequency
ALL
The maximum speed/frequency of the motor that the inverter
can drive.
The Max. value under vector control is five times weak
magnetic.
Factory default
:
50.00Hz
Range
:
10.00Hz~400.0Hz
E0-03
(
4003H
)
Min. speed/frequency
ALL
Frequency converter can drive the motor speed/frequency
minimum value
Factory default
:
0.00Hz
Range
:
0.00Hz~E0-02