SV800/SV800A User Manual 7 Detailed function description
153
HDI high speed pulse provides the torque compensation.
Pulse signal specification: 0KHz~100KHz, it can only be connected to high-speed pulse
terminal HDI.
5: Communication setting
Modbus communication controls the torque compensation. For details, please refer to the
Appendix Communication section.
No.
Name
Set range
Factory default
d1-09
Shuttle speed control selection
00
~
11
01
Units digit: Save after power off
0: Not save
The shuttle speed not save when power off.
1: Save
Save shuttle speed when power off.
Tens digit: positive/negative
0: No negative value during adjusting
1: Positive and negative value both valid
No.
Name
Set range
Factory default
d1-10
FWD/REV key control selection
0
~
1
0
0: Invalid.
1: Valid.