![SCOV SV800 Series Скачать руководство пользователя страница 133](http://html.mh-extra.com/html/scov/sv800-series/sv800-series_user-manual_1219567133.webp)
SV800/SV800A User Manual 6 Function Parameters List
125
H4: Multi-function pulse input and output
No.
Name
Content
Set value
H4-00
(7400H)
Pulse input HDI range
setting
ALL
0.10
~
100.00kHz
Factory default
:
20.00 kHz
Range
:
0.10
kHz~
100.00 kHz
H4-01
(7401H)
HDI gain setting
ALL
Factory default
:
100.00%
Range
:
0.00%~200.00%
H4-02
(7402H)
HDI bias setting
ALL
Factory default
:
0.0%
Range
:
-100.0%~100.0%
H4-03
(7403H)
HDI filter time
ALL
Factory default
:
0.10s
Range
:
0.00s~2.00s
H4-04
(7404H)
HDI Min. input
frequency
ALL
Factory default
:
1Hz
Range
:
1Hz~10kHz
H4-05
(7405H)
Multi-function pulse
output HDO function
ALL
0: No function
1: The set speed command
2: Motor speed
3: Inverter output frequency
4: Inverter output current
5: Inverter output voltage
6: DC bus voltage
7: Torque command
8: Input pulse frequency
9: Motor output torque
Factory default
:
0
Range
:
0~9
H4-06
(7406H)
HDO output range setting
ALL
Factory default
:
20.00kHz
Range
:
0.10KHz~100.00K
Hz