7 Detailed function description SV800/SV800A User Manual
150
9: Communications setting
The speed/ frequency command is set by the upper device communication control. For more
details, please refer to the Appendix communication section.
10: SPI communication setting
The speed/ frequency command is set by the SPI communication control which just suitable for
special inverter.
No.
Name
Set range
Factory default
d1-02
Auxiliary speed/frequency command input selection
0
~
11
0
0: Auxiliary frequency invalid
The auxiliary speed/frequency command is invalid and the speed/frequency command is only
related to d1-01.
1: Keyboard digital setting by E1-01 (Keyboard potentiometer valid)
The set speed/ frequency initial value is determined by the value of E1-01 and can be modified
by operating the potentiometer on the keyboard and setting of function code E1-01.
2: Keyboard digital setting by E1-01 (Keyboard potentiometer invalid)
The set frequency can only be modified by modifying the function code E1-01. The
potentiometer on the keyboard is invalid.
3: AI1
4: AI2
5: Reserved
6: Pulse setting HDI
7: Multi-segment instructions
8: Simple PLC
9: PID
10: Communication setting
11: SPI communication setting
The setting method of 3~11 is the same as that of d1-01. Please refer to the description in
d1-01
.
No.
Name
Set range
Factory default
d1-03
Auxiliary speed / frequency command coefficient
1%
~
100%
100%
When auxiliary speed /frequency selected in d1-05 (speed/frequency superposition), this
parameter is used to determine the adjustment range of the auxiliary speed/frequency command.
No.
Name
Set range
Factory default
d1-04
Auxiliary speed/frequency command coefficient
reference
0
~
1
0