SV800/SV800A User Manual 3 Mechanical Installation
23
3.3 Installation Guidance
The SV800 series inverter supports wall-mounted installation. You can follow below installation
instructions and in conjunction with specific model and application requirements of the
installation occasion to install the inverter.
As shown in
Fig.3-1
, the installation space needs to ensure that the frequency inverter has
sufficient heat sink space. Please consider the heat dissipation of other devices in the cabinet
when reserve the space.
Please mount the frequency inverter vertically to facilitate the upward emission of heat. If
there are multiple frequency inverters in the cabinet, please install them side by side. Please
refer to
Fig.3-3
and install a heat insulation flow guide plate in the case where the upper and
lower mounting is required.
When a mounting bracket is required, the material of the mounting bracket must be
flame-retardant
For applications with metal dust, it is recommended to use a mounting cabinet that can
completely close the inverter to completely isolate the inverter from metal dust. At this time, the
space in the fully sealed cabinet should be as large as possible. Installing the heatsink outside
the cabinet is also recommended.
3.3.1 Wall-mounted Installation
Fig. 3-5 Wall-mounted Installation