![SCOV SV800 Series Скачать руководство пользователя страница 50](http://html.mh-extra.com/html/scov/sv800-series/sv800-series_user-manual_1219567050.webp)
4 Electrical wiring and precautions SV800/SV800A User Manual
42
Type
Terminal symbol
Terminal name
Functional definition of the terminal
HDO-COM
High speed pulse
output
High-speed pulse output frequency range:
0~100KHz
Relay
output
M1-MG
NO terminal
(Normal open)
Functions can be programmed by
parameters.
Maximum contact capacity:
3A/240VAC
5A/30VDC
M2-MG
NO terminal
(Normal open)
TB-TC
NC terminal
(Normal close)
TA-TC
NO terminal
(Normal open)
Commu-
nication
terminal
A-B
Communication
terminal A-B
RS485 Communication port
CN3
Keyboard
interface
Connect to external keyboard (on the
control board)
PG
encoder
terminal
V+~GND1
Encoder power
supply
+ 24V, +12V, +5V optional output.
+ 24V sets by factory default..
1A+~1A-
Encoder 1 output
A signal
PG Closed Loop Encoder Interface
(Non-standard)
1B+~1B-
Encoder 1 output
B signal
1Z+~1Z-
Encoder 1
outputs Z signal
PG
encoder
terminal
2A+~2A-
Encoder 2 output
A signal
Position Closed Loop Encoder Interface
(Non-standard)
2B+~2B-
Encoder 2 output
B signal
2Z+~2Z-
Encoder 2
outputs Z signal
PE
Shield terminal
Encoder shield grounding
Note:
1.The default setting of the digital input port is common collector input. If you need to use common emitter
input, please "PW" and "COM" together with shorting link.
2.
The ground of digital output CM is internal isolated from the ground of digital input COM. When driving
with external power supply, CM and COM terminals cannot be shorted externally. But when driving with
in 24V, CM and COM should be short-connected in external.
The control circuit terminals mainly locate on the TB board which is connected to the control board through
CN1. The control board as shown in Fig. 4-10: