4 - INSTALLATION
THIS MANUAL IS PROPERTY OF SCM INDUSTRIA S.P.A - ANY TOTAL OR PARTIAL REPRODUCTION IS STRICTLY FORBIDDEN
Cap.
4
Pag.
47/53
4.4
ELECTRIC CONNECTION AND GROUNDING
(st-el_4-4_0.0)
DANGER-WARNING:
the installation operations must be performed by specialised technical personnel
SCM
or
personnel authorised by the manufacturer.
4.4.1
REQUISITES FOR THE ELECTRICITY SUPPLY SYSTEM
(st-el_4-4-1_0.0)
DANGER-WARNING:
the electric connection and subsequent controls must be carried out by a specialised electrician,
referring to the wiring diagram supplied with the machine.
Make sure that the main electric system of the factory can absorb the machine power and that earthing system
meets the norms in force.
In the connection point the supposed short-circuit current shall be lower than 5 kA
CSA
.
Make sure that the mains voltage corresponds to the machine one.
NOTE-INFORMATION:
the right working voltage is indicated on the plate fig.4.4; tolerance range: +/- 5%.
For voltage values out of this range you have to set the mains voltage.
Read out the value of the total absorbed current (Ampere) on the machine identification plate.