EN
3 - TECHNICAL SPECIFICATIONS
THIS MANUAL IS PROPERTY OF SCM INDUSTRIA S.P.A - ANY TOTAL OR PARTIAL REPRODUCTION IS STRICTLY FORBIDDEN
Cap.
3
Pag.
13/22
3.5
NOISINESS
LEVEL
(ev_3-5_0.0)
DECLARED DUAL-NUMBER NOISE EMISSION VALUES in accordance with ISO 4871
SAW
Operating conditions –
Cutting with circular saw
(according to norm EN 1870-1:2007+ A1:2009)
Cutting with circular saw
Measured size description
Reference
norm
Uncertainity
K
VSA
LAV
Operator station
Lop
: sound pressure
level at operator
station dB (A) and
peak level [dB(C)]
INPUT
EN ISO
11202:2010
4 dB
77
86
[95]
Lw
: sound power level dB (A)
EN ISO
3744:2010
2 dB
85
92
The maximum istantaneus noise level pressure is under 130 dB (C).
VSA
: Idle working without suction
LAV
: In operation