EN
4 - INSTALLATION
THIS MANUAL IS PROPERTY OF SCM INDUSTRIA S.P.A - ANY TOTAL OR PARTIAL REPRODUCTION IS STRICTLY FORBIDDEN
Cap.
4
Pag.
11/53
4.3.11
TABLE FOR SLIDING TABLE - INSTALLATION
(mmax_4-3-11_0.0)
1)
Remove sheet metal block (A fig. 4.3-11).
2)
Tighten up the screws again (B fig. 4.3-11).
3)
Position locking lever (C fig. 4.3-11) in closing cap housing (D fig. 4.3-11).
4)
Bring closing cap (D fig. 4.3-11) alongside wagon, ensure that tables are aligned and tighten the 4 screws (E
fig. 4.3-11).
5)
Tighten grub screw (F fig. 4.3-11) ensuring that it is inserted into hole of pin (G fig. 4.3-11).
6)
Remove lever blocking metal sheet from side opposite the wagon.
Lever (C fig. 4.3-11), is used to block carriage wagon into home position (wagon closed), and in loading piece to
machine position (wagon transferred to right hand limit switch).
Fig. 4.3-11