MorphoAccess® SIGMA Series - Administrator Guide
Compatibility with an Access Control System
2017_2000025464-v03
This document and the information therein are the property of Morpho. They must not
be copied or communicated to a third party without the prior authorization of Morpho
464
July 17
Internal Relay activation on Access Granted result
Description
If the result of the access rights check is successful, the internal relay may be optionally
activated, for example, to directly trigger a door switch.
The duration of the activation of the internal relay can be modified by a specific configuration
key.
Access control installation using internal relay offers a lower security level, than an installation
with a central access controller. In case of a centralized access, the decision to open the door is
taken by a central host, thus making the process more secure.
Figure 356:
Using the internal relay on the MorphoAccess® SIGMA Family terminal