July 17
d.
Feedback over TTL: Select Feedback over TTL, if controller feedback is to be
received on Wiegand String. The following parameters need to be configured,
only if Wiegand channel is used.
2.
Select Feedback Lines, it means the number of lines in which access controller will
send feedback to terminal. An administrator can select “One feedback line” or “Two
feedback line”
3.
Select Panel Mode as
a.
Accept/Reject: This mode indicates that access controller will only send
Accepted (Access Granted) or Rejected (Access Denied) feedback messages to
terminal
b.
Accept/Reject/PIN: Access Controller feedback consists of Accepted (Access
Granted), Rejected (Access Denied) and PIN (Asks user to enter PIN). This mode
is not applicable if Two Feedback Line is selected in previous step
4.
Enter Timeout within which the feedback is sent by controller to the terminal
5.
If Feedback Line is set as “One feedback line”, then each feedback message i.e.
Granted, Denied, and PIN can have different pulse width and pulse interval. An
administrator can define the same as below:
a.
High: If an administrator select High, then Pulse Width and Pulse Interval of the
feedback message will be as per system default value for high pulse
b.
Low: If an administrator select Low, then Pulse Width and Pulse Interval of the
feedback message will be as per system default value for low pulse
c.
Custom: If an administrator select Custom, then the field for editing Pulse Width
and Pulse Interval is enabled and an administrator can customize the pulse as
below:
i.
The Pulse Width can vary between 50 to 1000 milliseconds
ii.
The Pulse Interval can vary between 50 to 1000 milliseconds and value 0.
(When the pulse interval is set to 0 the terminal expects to receive one
pulse with the width specified by Pulse width setting)
d.
None: This option is available for Access Denied feedback only. It indicates that
on no response from controller feedback, for Access Denied, the terminal can
show timeout or access rejected message. You can configure whether to consider
timeout as reject. Refer step 6.
e.
Default value for customer fields is as below:
i.
For Access Granted – Pulse width and interval is 100ms, by default
ii.
For Access Denied – Pulse width and interval is 200ms, by default