
MorphoAccess® SIGMA Series - Administrator Guide
OSDP Protocol Support
2017_2000025464-v03
This document and the information therein are the property of Morpho. They must not
be copied or communicated to a third party without the prior authorization of Morpho
437
July 17
Demonstration of osdp_LED and osdp_TEXT command for MorphoAccess® SIGMA
terminal
The following is the sequence of communication between the CP and PD to update the Text and
LED color on MorphoAccess® SIGMA terminal as depicted in the Figure 348.
Sequence
Tx/Rx
Command/Response Syntax with Example
1
CP -> PD (Start/Request
of a command)
Syntax: osdp_TEXT (Reader Number, Text Command, Temp
Text time, Row, Column, Text Length, String)
Example: osdp_TEXT (0, 2, 0, 1, 1, 64, “HELLO WELCOME TO
SAFRAN!!)
2
PD -> CP (Response to a
command)
osdp_ACK in case of Success else osdp_NACK for failure
Example: osdp_ACK
3
CP -> PD (Start/Request
of a command)
Syntax: osdp_LED (Reader number, LED Number, Temp
Control Code, On time, Off time, On colour, Off colour,
Timer LSB/Timer MSB, Perm Control code, On time, Off
time, On colour, Off colour)
Example: osdp_LED (0, 0, 0, 0, 0, 0, 0, 0, 1, 10, 0, 2, 0)
Note: Timer value is applicable is only for Temporary LED
operation
4
PD -> CP (Response to a
command)
osdp_ACK in case of Success else osdp_NACK for failure
Example: osdp_ACK
Figure 351:
OSDP LED and TEXT Screen on MorphoAccess® SIGMA terminal
OSDP LED
OSDP Text