MorphoAccess® SIGMA Family Administrator Guide
MorphoAccess® Terminal Administration Menu
2017_2000025464-v03
This document and the information therein are the property of Morpho. They must not
be copied or communicated to a third party without the prior authorization of Morpho
237
July 17
Figure 209:
Entering Communication Port
2.
Enter Communication Port: port that will be used for TCP (plain text)
3.
Use “
” button to save
Enabling TCP Channel
Transmission Control Protocol (TCP) is a protocol that is used for transmission of the
input/output messages between the MorphoAccess® SIGMA Family terminal and distant
systems, such as external controllers or Webserver application, connected through
Ethernet/Wi-Fi™.
By default, the TCP Channel is enabled. If the administrator has disabled this parameter, the
terminal will not be able to communicate (i.e. input or output of messages) with distant systems
using Ethernet/Wi-Fi™.
Access Path
Access point
Access Path
SIGMA Series
SIGMA Extreme
Series
SIGMA Lite
Series
Terminal
Menu
Security Menu > Communication >
TCP Channel
✔
✖
Webserver
Terminal
Settings
>
Communication > Communication
Channels Configuration
✔
✔