MorphoAccess® SIGMA Family Administrator Guide
MorphoAccess® Terminal Administration Menu
2017_2000025464-v03
This document and the information therein are the property of Morpho. They must not
be copied or communicated to a third party without the prior authorization of Morpho
223
July 17
Parameter
Values
Format Type
Description
15
wiegand_fmt_custom_slot5
Custom Wiegand format
slot 5
16
wiegand_fmt_custom_slot6
Custom Wiegand format
slot 6
17
wiegand_fmt_custom_slot7
Custom Wiegand format
slot 7
Here, Custom Slot indicates the customer format defined for sending Wiegand String.
Custom Format can only be set in parameter, if format is defined in corresponding slot.
Configure parameter “remote_msg_conf.interface” is set as value ‘3’, which indicates
communication is done using Wiegand channel
An administrator can also set Clock and Data Identifier for sending alarm message, 65535
(0 – 65535). See “
”.
For output to be sent in Clock and Data format, External port output type should be
selected as Clock and Data. See “
Tamper Alarm message using UDP
The administrator can configure the terminal to send an alarm message to a distant system, in
case of a tamper event. This communication can happen through Ethernet (or Wi-Fi™), using
UDP protocol.
The
administrator
needs
to
configure
parameters
such
as
“remote_msg_ip_conf.host_1_protocol” to 1. This is for enabling communication using UDP
protocol
Parameter Name
Parameter
Values
Format
Type
Description
remote_msg_ip_conf.host_1_protocol
0
Host_TCP
uses TCP protocol for
communication (Default)
1
Host_UDP
uses UDP protocol for
communication
2
Host_SSL
uses SSL over TCP for
communication