Remote Commands
R&S
®
Spectrum Rider FPH
356
User Manual 1321.1011.02 ─ 06.00
Example:
CORR:TRAN:ISOT?
only an example
13.6.3
Remote Commands of the Analog Modulation
The chapter provides information on remote commands that configure and perform
analog modulation measurements.
Availability of remote commands for the analog modulation
Note that the listed remote commands take effect only if R&S FPH-K7 is installed on
the R&S Spectrum Rider
...........................................................................................356
...................................................................................... 357
......................................................................................... 357
....................................................................................358
.....................................................................................359
..................................................................................... 359
............................................................................360
Reading out Measurement Results
.......................................................................361
13.6.3.1
Setting the Frequency
The following chapter describes command to define and query on the frequency set-
tings
List of commands
●
●
●
CALCulate<1...2>:MARKer:FUNCtion:ADEMod:AFRequency[:RESult]?
CALCulate<1...2>:MARKer:FUNCtion:ADEMod:AFRequency[:RESult]?
This command queries the modulation frequency.
The numeric suffix at CALCulate is irrelevant for this command
Suffix:
<1...2>
.
1...2
Example:
CALC:MARK:FUNC:ADEM:AFR?
Reads out the modulation frequency
Usage:
Query only
Remote Control - Commands