Remote Commands
R&S
®
Spectrum Rider FPH
354
User Manual 1321.1011.02 ─ 06.00
●
[SENSe:]ESPectrum:PRESet:SETTings
●
[SENSe:]ESPectrum:PRESet[:STANdard]
<FileName>
This command loads one of the predefined spectrum emission masks for a telecommu-
nications standard.
Parameters:
<FileName>
String containing the filename of the spectrum emission mask.
Example:
ESP:PRES 'W-CDMA 3GPP.semstd'
Loads the SEM for 3GPP WCDMA.
[SENSe:]ESPectrum:PRESet:SETTings
<ONCE>
This command optimizes the settings for the SEM measurement.
This command is an event and therefore has no query and no *RST value.
Parameters:
<ONCE>
ONCE
Example:
ESP:PRES:SET ONCE
Initializes an adjustment of the settings.
Usage:
Setting only
[SENSe:]SWEep:MODE
<SweepMode>
This command turns the spectrum emission mask measurement on and off.
Parameters:
<SweepMode>
LIST | ESPectrum | AUTO
LIST
Turns on the Spurious Emission measurement.
ESPectrum
Turns on the SEM measurement.
AUTO
Turns on the Spectrum mode.
*RST:
AUTO
Example:
SWE:MODE ESP
Starts the SEM measurement.
Using an Isotropic Antenna
This chapter describes all commands available to set up measurements with an iso-
tropic antenna.
You can use an isotropic antenna with all measurement modes that are described
above.
Remote Control - Commands