Remote Commands
R&S
®
Spectrum Rider FPH
345
User Manual 1321.1011.02 ─ 06.00
Parameters:
<TxChannelSpacing> *RST:
20 kHz
Default unit: GHz
Example:
See
[SENSe:]POWer:ACHannel:TXCHannel:COUNt
[SENSe:]POWer:ACHannel:TXCHannel:COUNt
<#ofTxChannels>
This command defines the number of transmission channels.
The command is available for measurements with span > 0.
Parameters:
<#ofTxChannels>
Range:
1 to 12
*RST:
1
Example:
CALC:MARK:FUNC:POW:SEL CPOW
Selects the channel power measurement.
POW:ACH:TXCH:COUN 2
Defines 2 transmission channels.
POW:ACH:ACP 2
Defines 2 pairs of neighboring channels to the left and right of
the TX channel(s).
POW:ACH:SPAC:CHAN2 20KHZ
Defines a distance of 20 kHz between the first and the second
Tx channel.
POW:ACH:BAND:CHAN2 120KHZ
Defines a bandwidth of 120 kHz for the second TX channel.
POW:ACH:REF:TXCH:MAN 2
Selects the second Tx channel as reference channel.
POW:ACH:SPAC 10KHZ
Defines a distance of 10 kHz from the TX channel to the adja-
cent channel.
POW:ACH:BAND:ACH 120KHZ
Defines a bandwidth of 120 kHz for the adjacent channel.
POW:ACH:SPAC:ALT 20KHZ
Defines a distance of 20 kHz from the adjacent to the first alter-
nate channel.
POW:ACH:BAND:ALT 120KHZ
Defines a bandwidth of 120 kHz for the first alternate channel.
ACLR Limit Check
The following commands configure and perform limit checks when measuring the adja-
cent channel power.
List of commands
●
CALCulate<1...2>:LIMit<1...2>:ACPower:STATe
Remote Control - Commands