50 • Chapter 3: Operation
GX-6000 Operator’s Manual
Peak Screen
The peak screen displays the highest (lowest for oxygen) concentrations detected since the
GX-6000 was turned on. Peak readings are stored in the GX-6000’s memory until a higher
level is detected (lower for oxygen), the peak reading is cleared, or the GX-6000 is turned
off.
The lunch break feature enables the GX-6000 to save peak readings when it is turned off
so it can continue them when it is turned on again. See “Turning On the GX-6000” on
page 25.
To clear the peak readings, do the following:
1 . With the Peak Screen displayed, press and hold the RESET button. The following
screen sequence will occur.
2 . Release the RESET button. The peak readings will be reset and the unit will return to
the Peak Screen.
If you do not want to clear the peak readings, release the RESET button before the
above screen sequence occurs. The unit will return to the Peak Screen.
PEAK
CH4 O2
%LEL %
H2S CO
ppm ppm
VOC
ppm
10 15.0
13.0 200
2000
PEAK
PEAK CLEAR
HOLD
PEAK
PEAK CLEAR
RELEASE