Introduction
2-2
CardioMD Service Manual
1MAN0158-H11 04-2005 CSIP Level 1
2.1
Introduction
CardioMD is a nuclear medicine gamma camera system intended for cardiac imaging. A dedicated
acquisition PC executes all acquisition protocols.
Acquisition data from the PC can be sent via DICOM to a workstation for further processing.
For use with the CardioMD system, Philips Medical Systems offer a choice of two processing
stations:
•
The Pegasys Ultra™ workstation
•
The JET
Stream
® Workspace Cardiology Module.
For further information on these, please refer to the relevant workstation documentation
DICOM (Digital Imaging and Communications in Medicine) is a NEMA standard that defines a
means of exchanging image files and other information between DICOM compliant devices.
DICOM provides image network file transfer capabilities between the CardioMD acquisition PC
and the workstation.
Note
. DICOM data transfer between the CardioMD and any workstation other than those
specified above is not a valid configuration and is not supported.
2.2
System Components
The system architecture is illustrated in the schematic block diagram below.
Table
Longitudinal
drive
Detector
Vertical
drive
Detector
Horizontal
drive
Table Pallet
Detector 2
Detector 1
Detector
Rotate
Drive
Motion
Control
Gantry
Interface
AC
Mains
Handset
IEEE 1394
Firewire
Power
Supply
Acq. PC
Power
IEEE 1394 Firewire
CANbus
Collimator
Collimator
Safety Module
Gantry
E
Stop
Collision Sensor
Collision Sensor
Sense
Sense
EKG
Acquisition
Station
Handset
Network
Figure 2.1 CardioMD system components
2.2.1
Gantry
The gantry forms the basis of the CardioMD gamma camera. All external devices are connected to
the gantry from where the signals are distributed to the various system components. The gantry
contains most of the system’s electronics, such as power supplies, motors and motion controllers.
Содержание CARDIOMD
Страница 1: ...CARDIOMD SERVICE MANUAL 1MAN0158 H11 04 2005 CSIP Level 1 ...
Страница 10: ...Introduction x CardioMD Service Manual 1MAN0158 H11 04 2005 CSIP Level 1 ...
Страница 16: ...Safe Operating Practices 1 6 CardioMD Service Manual 1MAN0158 H11 04 2005 CSIP Level 1 ...
Страница 164: ...Detector Calibration Files 5 60 CardioMD Service Manual 1MAN0158 H11 04 2005 CSIP Level 1 ...
Страница 207: ...Installation 1MAN0158 H11 04 2005 CSIP Level 1 CardioMD Service Manual 8 5 Figure 8 2 System footprint with short table ...
Страница 232: ...Installation 8 30 CardioMD Service Manual 1MAN0158 H11 04 2005 CSIP Level 1 Figure 8 17 Installation template ...
Страница 328: ...Installation Procedures 9 38 CardioMD Service Manual 1MAN0158 H11 04 2005 CSIP Level 1 ...
Страница 348: ...Planned Maintenance Procedures 11 6 CardioMD Service Manual 1MAN0158 H11 04 2005 CSIP Level 1 ...
Страница 465: ......