85
Example 3
This example shows execution when a target position designated from the
origin (i.e., not an increment) is exceeded during deceleration for STOP, as
can happen when STOP is executed during the end of a continuous position-
ing action. If START is next executed before this situation is corrected, the
feeding direction for the action will be wrong, and an error (code 5020) will be
generated due to inability to begin the action. The Unit can be restarted after
manually feeding (with JOG) back to the other side of the target position for
action #0.
1
0
1
0
0
1
1
0
1
1
0
#0
0
5020
Time
0
START
word n, bit 00
STOP
word n, bit 15
(or external interrupt)
Pulse output
Positioning completed flag
word n+5, bit 00
Error flag
word n+5, bit 05
Busy flag
word n+5, bit 12
STOP executed flag
word n+5, bit 15
Error code
word n+6
Positioning action number
word n+7, bits 07-00
Target position for
action #0 is passed.
Target speed #5
This error will also be generated if the target position for action #0 is ex-
ceeded through manual operations before START is executed following
STOP.
External Interrupt Commands
Section 4–10
Содержание SYSMAC C200H-NC111
Страница 1: ...Cat No W137 E1 04 Position Control Unit SYSMAC C200H NC111...
Страница 2: ...SYSMAC C200H NC111 Position Control Unit Operation Manual Revised September 2003...
Страница 3: ...iv...
Страница 5: ...vi...