3
Indicators
RUN: indicates operation
is in progress
CW: indicates controlled system
(motor) is revolving clockwise
CCW: indicates controlled system
(motor) is revolving counterclockwise
BUSY: indicates operation/transfer
is in progress
ALARM: blinks when an abnormality
has occurred
ERROR: lights when an error has oc-
curred
Setting switches
MACHINE No.
MODE
Allocates a unit number (0 to 9) to
the Position Control Unit
Not used
Connector
Used to connect the Position
Control Unit to a stepping mo-
tor driver or servomotor driver.
Attach the enclosed connector
to the proper cable.
When setting the switches, use a
screwdriver if necessary.
Do not apply an excessive force to the
switches.
Do not leave the switches halfway be-
tween two setting points or the Position
Control Unit may malfunction.
Before operating these switches, make
sure that power to the PC is off.
Indicators
Position Control Unit indicators (LEDs) are used to quickly determine operat-
ing status. They are particularly valuable in initial system activation and de-
bugging, but can also be used to monitor and check Unit operation.
Indicator
Color
Function
Lit during normal operation. Goes out for errors.
Lit during output of CW (clockwise) pulses.
Lit during output of CCW (counterclockwise) pulses.
Lit during positioning or data transfer.
Flashing when a BCD error exists in initial data, speed
data, or positioning data updated with TRANSFER DATA.
Lit when an error has occurred causing operation to stop.
Green
Green
Green
Green
Red
Red
RUN
CW
CCW
BUSY
ALARM
(flashing)
ERROR
1–3
System Configuration
The basic system configuration is shown below. Position Control Unit outputs
are connected to a motor driver, either for a stepping motor or for a ser-
vomotor (either AC or DC) capable of receiving pulse train inputs. The Unit is
controlled by inputs from devices and/or a control panel. It, in turn, outputs
pulse trains and direction signals to control the motor driver.
System Configuration
Section 1–3