83
STOP Executed
During START
When the STOP command bit is set during execution of a positioning action
under START, the positioning completed flag is not turned ON, and the posi-
tioning action number is not changed. When START is next executed, the
target position and speed of that action will be used, as long as the target
position has not been exceeded. The busy flag, however, turns OFF, allowing
manual operations to be used up to the next START.
Let’s take, for example, a case in which the following DM words and data are
used.
Completion code: continuous
Target position
Completion code: single
Target position
15 00
Target speed #5
Target speed #8
Positioning action #0
Positioning action #1
m+22
m+23
m+24
m+25
m+26
m+27
5
8
2
0
Example 1
First of all, the following diagram shows the situation when STOP is not exe-
cuted.
1
0
1
0
1
0
Time
START
word n, bit 00
Positioning completed flag
word n+5, bit 00
Busy flag
word n+5, bit 12
START
Target speed #5
Target speed #8
Target position for action #0
#0
Stop (at target position
for action #1)
External Interrupt Commands