123
Appendix B
Error Code List
Error
START
Direction reversed
CW limit
CCW limit
Present position
undefined
Stopped at CW
limit
Stopped at CCW
limit
Manual CW limit
Manual CCW limit
ORIGIN SEARCH
disabled
Error code
5000
5020
5030
5031
5040
5060
5061
5070
5071
5100
Problem
Pulses cannot be output for START
command because of data that gener-
ated an alarm. This data includes the
initial speed, initial positioning action
number, acceleration, deceleration,
backlash compensation, internal CW
limit, internal CCW limit, speed and de-
sired position.
Pulse output is not possible because the
direction was reversed following a con-
tinuous positioning action.
Pulse output is not possible because the
internal CW limit would be passed.
Pulse output is not possible because the
internal CCW limit would be passed.
Execution of START, TEACH, or ORI-
GIN RETURN is not possible because
the present position has not been estab-
lished.
An attempt was made to feed clockwise
using HIGH-SPEED JOG, LOW-SPEED
JOG, or INCH following RELEASE
PROHIBIT after feeding had been
stopped at CCW limit.
An attempt was made to feed counter-
clockwise using HIGH-SPEED JOG,
LOW-SPEED JOG, or INCH following
RELEASE PROHIBIT after feeding had
been stopped at CCW limit.
The internal CW limit was reached and
feeding stopped during execution of
HIGH-SPEED JOG, LOW-SPEED JOG,
or INCH.
The internal CCW limit was reached and
feeding stopped during execution of
HIGH-SPEED JOG, LOW-SPEED JOG,
or INCH.
ORIGIN SEARCH cannot be executed
because of data for the origin compen-
sation, search speeds, or backlash com-
pensation that generated an alarm code.
Correction
Read out alarm code, correct data
accordingly, and TRANSFER DATA
or RESTART. The error code will
be erased for the next START if
data has been properly corrected.
Check positioning actions,correct
data accordingly, and TRANSFER
DATA or RESTART.
Execute ORIGIN SEARCH, RE-
SET ORIGIN, or preset the present
position with TRANSFER DATA.
Feed counterclockwise.
Feed clockwise.
Read out alarm code and correct
data accordingly.
(continued)