106
Operation
10002
SW
ORIGIN SEARCH
The possible search patterns for ORIGIN SEARCH using both an origin sig-
nal and an origin proximity signal are as follows.
CCW
CCW
CCW
CW
CW
CW
Origin proximity signal
Pulse output
Origin (Stop)
CW limit
1
0
START
START
Origin (Stop)
START
Origin (Stop)
5–8
Using Zones to Control Jogging
Operation
This examples shows how to use zones to change conditions for manual op-
erations (jogging and inching). With the following setup and data, all manual
operations are possible in zone 0 except for the part of it occupied by zone 1.
Using Zones to Control Jogging
Section 5–8