47
2: Continuous
As soon as the target position for the first positioning action is reached, the
next positioning action is started. The first target position is reached at the
target speed set for the next positioning action, so that the next positioning
action can be executed immediately.
Time
Target position for first
positioning action
Target speed for first
positioning action
START
Target speed for next po-
sitioning action
3: Bank end
The term ”bank” refers to a combination of several positioning actions or se-
quences. The target position and target speed are reached and feeding
stops. The next positioning action to be executed will be the initial positioning
action number in bits 07-00 of DM word m. START is required in order to re-
sume execution of positioning actions.
Target speed
Stop
Time
START
4: Extended
The Unit continually outputs pulses at the speed set for the positioning ac-
tion. The Unit will not calculate the present position, and the no-origin flag (bit
11 of word n+5) will go ON during operation. The direction of pulse output is
determined by the direction digit set in the positioning data. (See Appendix C
DM Area Allocations.) Extended positioning actions are terminated with
STOP. START is required in order to resume execution of positioning actions.
Stop
Time
STOP executed
START
Target speed
Dwell Time
DM word m+22, bits 07-04
Set to a value between 0 and F (hex). (Unit: 0.1 s)